Install Instructions

ENGLISH
WWW.STIEBEL-ELTRON-USA.COM GALAXY
AUTOMATIC HAND DRYERS | 9
PREPARATION
min 4Ý (102 mm)
48Ý (1219 mm)
Mount the hand dryer at least 48˝ (1219 mm) above the floor.
8. Preparation
The Galaxy
hand dryer must have its own independent circuit using 3 wire cable
of the appropriate size protected by a correctly rated double-pole circuit breaker.
The Galaxy
1 unit for 110 120 V requires a 20 A circuit breaker and AWG 12 copper
wire. The Galaxy
2 unit for 220 240V or 208 V requires a 15 A circuit breaker and
AWG 12 copper wire.
f Transfer the four mounting points to the wall and trace the electrical wiring
entry point using the enclosed drilling template.
f Feed the electrical wiring through the entry point traced with the template.
f Remove the two screws at the air outlet grill and the screw on the locking slide.