Install Instructions
8 | GALAXY
™
AUTOMATIC HAND DRYERS WWW.STIEBEL-ELTRON-USA.COM
MINIMUM CLEARANCES
24”
(600
mm
)
24”
(600
mm
)
89”
118”
(3000
mm
)
(2250
mm
)
1
2
3
0
0 Danger zone: do not install unit in bathtubs showers, or wash basins.
1 Danger zone: do not install directly above bathtubs or showers.
2 Danger zone: do not install within 24˝ (600 mm) of bathtubs or showers
3 Safe area: unit must be installed in this area, outside of danger zones 2, 1 and
0.
5
Ý
(127 mm)
12
Ý
(PP)
min 4ÝPP
1½
Ý
PP
f Before mounting the unit to the wall, ensure all minimum distances are met for
safety and performance considerations.
f The unit must be installed at least 4˝ (102 mm) from perpendicular walls.
f The unit must be installed at least 12˝ (305 mm) above countertops to avoid
splashing the unit.
f Ensure the air outlet is not obstructed