User's Manual

13.56 MHz
Upgradable readers ARC
Installation instructions
13,56 MHz
Lecteurs évolutifs ARC
Notice d’installation
13.56 MHz
Lectores escalables ARC
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1097C15 - Page 1 sur 12 - Ed. 25/01/2021
Product references
Power supply characteristics
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main
supply.
Main power supply: Range: +7 Vdc to +28 Vdc Typical: 12 Vdc
Max. consumption at 12 Vdc:
ARC-A: 130 mA
ARC-B: 160 mA
ARC-D: 280 mA
ARC-E: 310 mA
ARC-F: 350 mA
ARC-J: 190 mA
ARC-K: 230 mA
ARC-AQ: 260 mA
ARC-CQ: 330 mA
Characteristics
Communication: RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock and Data)
Connection: Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch
Protection: IP65, excluding connectors
Static relay: ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1 Ω typical for AC/DC
Recommended cables
RS485: Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft at 9600 baud
RS232: Max. length 49.2 ft
Wiegand / Clock & Data: Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 98 ft max / 4 wires AWG24 197 ft max / 6 wires AWG24 328 ft max
2 wires AWG20 164 ft max / 4 wires AWG20 328 ft max
Buzzer / LED
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the remote system with a 0 Vdc
respectively on the Led 1”, “Led 2” and “Buzzer” inputs of the reader’s connector or controlled by the communication protocol of the reader (W3x).
Anti-tearing
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of
reader.
for R/S 31/x1: the wrenching signal will be emitted on the “Data/Data1” line. This function is configurable via a configuration card.
for R/S 32/33/x2/x3 and OSDP
TM
: the reader will perform the operations configured with the configuration card.
for W 32/33/x2/x3: the reader will perform the operations configured with the SSCP protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Relay
Read-only reader: automatic tamper management (except touch screen) or activated on the reading of a valid identifier
Touch screen read-only reader: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read/Write & OSDP
TM
readers: the relay is controlled by the SSCP/ OSDP
TM
protocol commands.
UHF default configuration settings
Reader powered off. The defaults reader settings can be stored in internal memory accessible by UHF RFID technology. They will be taken into account when
the reader is powered on.
Read-only reader configuration
R and S readers are configurable with the SCB configuration card created with SECard. OSDP
TM
readers are configurable with OCB configuration card:
If the SCB/OCB is compatible with the reader’s firmware, the LED lights green and the buzzer beeps five times.
If the SCB/OCB is not compatible with the reader’s firmware, the LED lights red and the buzzer is activated for 1 s.
If the SCB/OCB key is different from the reader’s key: no reaction.
Caution: set your reader with your own company key.
Powering-up the readers
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only and OSDP
TM
readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial R/S ARC only: the orange LED flashes 20 times: waiting for an update.
4. Activation of the default LED (read-only: flashes blue, OSDP
TM
: off; if no customer specific configuration).
5. ARC Screen: display of the default image and keypad activation by touching the screen.
For the ARC screen with an activated keypad, the default mode is displaying the picture on standby and activate the keyboard by pressing the screen.
Precautions for the biometric sensor and keypad
For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
The keypad is sensitive. Take off your gloves to enter your code.
ARC-X
X:
A: Standard
B: Keypad
C: Touch screen
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
I : Standard + 125 kHz module
J : Keypad + 125 kHz module
K : Touch screen + 125 kHz module
AQ: Standard + QR Code module
BQ: Keypad + QR Code module
CQ: Touch Screen + QR Code module
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
Connector
Type
J4
Wiegand
Clock & Data
RS232
RS485
1
0 Vdc
2
+Vcc (+7 Vdc to +28 Vdc)
3
D0
Code
NC
NC
4
D1
Data
NC
NC
5
Clock
Clock
NC
NC
6
NC
NC
Tx
L+
7
NC
NC
Rx
L-
8
Led 1
9
Led 2
10
Buzzer
US
FR
ES