Wiring resistors R1 and R2 use the extended features of the
RS485 Bus: FAIL-SAFE (see RS485-AN-960).
R1 & R2: 1.5 kΩ resistor supplied.
R
T
: 120 Ω end-of-line resistor supplied.
Le câblage des résistances R1 et R2 permet d’utiliser des
propriétés étendues du BUS RS485 : FAIL-SAFE (cf. RS485-
AN-960).
R1 et R2 : résistances de 1.5 kΩ fournies.
R
T
: résistance de fin de ligne de 120 Ω fournie.
Cableado de las resistencias R1 y R2 para utilizar las funciones
extendidas del bus RS485: FAIL-SAFE (ver RS485-AN960).
R1 y R2: resistencia de 1.5 kΩ incluida.
R
T
: resistencia de final de línea de 120 Ω incluida.
Power supply characteristics
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply: Range: +7 Vdc to +28 Vdc Typical: 12 Vdc
Max. consumption at 12 Vdc:
ARC-A/PH5: 130 mA
ARC-B/PH5: 160 mA
ARC-C/PH5: 200 mA
ARC-D/PH5: 280 mA
ARC-E/PH5: 310 mA
ARC-F/PH5: 350 mA
ARC-I/BF5: 160 mA
ARC-IM/BF5: 170 mA
ARC-J/BF5: 190 mA
ARC-JM/BF5: 200 mA
ARC-K/BF5: 230 mA
ARC-KM/BF5: 240 mA
ARC-AQ/PH5: 260 mA
ARC-BQ/PH5: 290 mA
ARC-CQ/PH5: 330 mA
Recommended cables
RS485: Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft at 9600 baud
RS232: Max. length 49.2 ft
Wiegand / Clock & Data: Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 – 98 ft max / 4 wires AWG24 – 197 ft max / 6 wires AWG24 – 328 ft max
2 wires AWG20 – 164 ft max / 4 wires AWG20 – 328 ft max
Anti-tearing
Tearing is detected by an accelerometer.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Bell
Touch screen read-only readers: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read-only reader configuration
R and S readers are configurable with SCB RFID configuration card.
OSDP
TM
readers are configurable with OCB RFID configuration card or with FileTransfer command.
▪ If the SCB/OCB is compatible with the reader’s firmware, the LED lights green and the buzzer beeps five times.
▪ If the SCB/OCB is not compatible with the reader’s firmware, the LED lights red and the buzzer is activated for 1 s.
▪ If the SCB/OCB key is different from the reader’s key: no reaction.
Caution: set your reader with your own company key.
Powering-up the readers
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only & OSDP
TM
readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
4. Activation of the default LED (read-only: flashes blue, OSDP
TM
: off; if no customer specific configuration).
5. For the ARC screen with an activated keypad, the default mode is: display the picture on standby and activate the keyboard by pressing the screen.
Precautions for the biometric sensor and the keypad
▪ For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
▪ The keypad is sensitive. Take off your gloves to enter your code.
Precautions for installation
▪ The supply voltage at the reader’s connector should be between +7 Vdc and +28 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference depending on their radiation level and the proximity of the reader.
▪ Recommended distance between two readers: parallel plane: 11.81 in – same plane: 15.75 in – perpendicular plane: 9.8 in.
▪ Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
▪ If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
▪ By design, the reader can be installed indoors and outdoors.
▪ BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
▪ Operating temperature:
Declaration of compliance
STid declares that the ARC-X reader is compliant to the essential requirements of the Directives RED 2014/53/EU, RoHS 2011/65/EU and Delegated directive. A copy of our declaration is available on
request from qualite@stid.com.
This device complies with part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation
NOTE: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such
modifications could void the user’s authority to operate the equipment.
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use and with §1.1307(b),
2.1091 and 2.1093 of the FCC rules Title 47 CFR Ch. I.
The maximum magnetic field level of the device is:
▪ 12 dBµA/m (at 10 meters) for 13.56 MHz frequency.
▪ 25 dBµA/m (at 3 meters) for 125 kHz frequency (ARC-I, ARC-J and ARC-K).
▪ -9 dBµA/m (at 10 meters) for 125 kHz frequency (ARC-IM, ARC-JM and ARC-KM).
Temperature
-22 °F to 158 °F
-30°C to +70°C
-22 °F to 140 °F
-30°C to +60°C
-4 °F to 158 °F
-20°C to +70°C
-4 °F to 140 °F
-20°C to +60°C
14 °F to 122 °F
-10°C to +50°C
Readers
A, B, IM, JM
AQ, BQ
C, I, J, K, KM
CQ
D, E, F