Instruction Manual
Safety Technology International, Inc.
2
306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Toll Free: 800-888-4784 • E-mail: info@sti-usa.com
Web: www.sti-usa.com
Safety Technology International (Europe) Ltd.
U
nit 49G Pipers Road • Park Farm Industrial Estate • Redditch
W
orcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com • Web: www.sti-europe.com
TERMINAL STRIP
BATTERY CONNECT
9 VDC BATTERY
#801 KEY
ELECTRONICS
LENS COVER
REED SWITCH AND MAGNET
(INSTALL INSIDE CABINET)
REED SWITCH WIRE
19018 ANCHOR #8–10
3/16 DIAMETER HOLE (2) PLACES
KEY SWITCH WIRE
0
9723 KEY SWITCH PLATE
BASE PLATE
TERMINAL STRIP
REED SWITCH WIRE
(NOT POLARITY SENSITIVE)
KEY SWITCH WIRE
(NOT POLARITY SENSITIVE)
D
C
I
N
+
-
K
E
Y
S
W
I
T
C
H
A
L
A
R
M
S
W
I
T
C
H
N
C
C
O
M
N
O
I
NSTALL PLASTIC ANCHORS INTO WALL.
R
OUTE KEY SWITCH AND REED SWITCH WIRES FROM BEHIND KEY SWITCH PLATE
THROUGH HOLES IN BOTH PLATES (AS SHOWN).
ATTACH BOTH PLATES TO WALL WITH (2) #8 x 1-1/4 in. SCREWS.
(
BE SURE ALL WIRES ARE PROTECTED FROM VIEW BEHIND KEY SWITCH PLATE.)
STEP 4
FEED WIRES THROUGH ELECTRONICS PLATE
MOUNT ELECTRONICS TO BASE PLATE.
CONNECT REED SWITCH WIRES TO TERMINAL STRIP.
CONNECT BATTERY.
INSTALL LENS COVER.
CLOSE CABINET DOOR.
TURN KEY SWITCH ON.
OPEN CABINET DOOR TO TEST.
STEP 5
MAY 2008 7535AED QUICK INSTALL