User's Manual
Applications
Crescendo UHF Half-Duplex User Manual Page 51 of 78
7.3.2 Hayes Dial-up Network with Repeaters
Repeaters can be used to extend the range of a Hayes dial-up network, as shown in Figure 20.
Crescendo
Base
1000
Crescendo
Repeater
2000
Main
DTE
RADIO CONFIGURATION
Rx Address: 2000
Store and Forward Repeater: True
Repeaters in Network: 2
ROUTING TABLE
Route 3000-3999 to 3000
PROTOCOL CONFIGURATION
Main Port: Hayes Dial-up
SERIAL CONFIGURATION
Main Port: 38400, 8N1, Hardware Flow
RADIO CONFIGURATION
Rx Address: 1000
Repeaters in Network: 2
ROUTING TABLE
Route 2000-3999 to 2000
PROTOCOL CONFIGURATION
Main Port: Hayes Dial-up
SERIAL CONFIGURATION
Main Port: 38400, 8N1, Hardware Flow
Crescendo
Repeater
3000
DTE
RADIO CONFIGURATION
Rx Address: 3001
Repeaters in Network: 2
ROUTING TABLE
Route 1000-3999 to 3000
PROTOCOL CONFIGURATION
Main Port: Hayes Dial-up
SERIAL CONFIGURATION
Main Port: 38400, 8N1, Hardware Flow
Main
DTE
Main
Crescendo
Remote
3001
RADIO CONFIGURATION
Rx Address: 3000
Store and Forward Repeater: True
Repeaters in Network: 2
ROUTING TABLE
Route 1000-2999 to 2000
PROTOCOL CONFIGURATION
Main Port: Hayes Dial-up
SERIAL CONFIGURATION
Main Port: 38400, 8N1, Hardware Flow
DTE
Main
Figure 20: Hayes dial-up network with repeaters
The following dial string is used to dial the second main port on the second store-and-forward repeater:
ATD300000<CR>
To dial the main port on the remote, the following dial string is used:
ATD300100<CR>