User's Manual
Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 97 of 134
Triggers Combined (Stored)
Allows this fault to assert the combined alarm (COMB) in addition to it's configured alarm.
ATI169[a]: Returns the current value of Triggers Combined.
ATI169[a]=n sets Triggers Combined to n.
Enumeration values:
0 = False
1 = True
Where: a = Faults table index (starting from 0).
Go Standby (Stored)
Configures this fault as a TX FAULT for the purposes of entering standby mode when Hot Standby
operation is enabled
ATM17[a]: Returns the current value of Go Standby.
ATM17[a]=n sets Go Standby to n.
Enumeration values:
0 = False
1 = True
Where: a = Faults table index (starting from 0).
Counter (Stored)
The number of times this fault has occurred since the statistics were reset.
ATI171[a]: Returns the current value of Counter.
ATI171[a]=n.: Sets the value of Counter to n , given that 0 <= n <= 65535.
Where: a = Faults table index (starting from 0).
Faults Overview Table
Fault
ATI159[a]: Returns the current value of Fault.
Where: a = Faults Overview table index (starting from 0).
Status
ATI160[a]: Returns the current value of Status.
Enumeration values:
0 = Inactive
1 = Active
2 = Latched
3 = Fleeting
Where: a = Faults Overview table index (starting from 0).
Active Duration
ATI161[a]: Returns the current value of Active Duration.
Where: a = Faults Overview table index (starting from 0).
Counter
ATI162[a]: Returns the current value of Counter.
Where: a = Faults Overview table index (starting from 0).
Encoder Interface Menu
Encoder Detected