User's Manual

Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 96 of 134
1 = Can only reset fault actions.
2 = Cannot latch a fault.
3 = Changing this requires elevated access rights.
4 = Cannot clear. This source of this fault is still active
5 = Fault actions cannot have fault actions.
6 = This fault must have a latching mechanism.
7 = Cannot select this Alarm - it is being used by the Hot-Standby feature.
8 = The currently selected reference mode (Radio->Reference->Reference Mode) requires this fault to use
the Reference Switchover fault action.
Fault Action (Stored)
Configured action to be taken when this fault occurs.
ATI167[a]: Returns the current value of Fault Action.
ATI167[a]=n sets Fault Action to n.
Enumeration values:
0 = None
1 = Reference Switchover
2 = Disable Transmit
3 = Scale Transmit Power
4 = Enable Current Foldback
5 = Enable Reverse Power Foldback
Where: a = Faults table index (starting from 0).
Can return the following error codes:
1 = Can only reset fault actions.
2 = Cannot latch a fault.
3 = Changing this requires elevated access rights.
4 = Cannot clear. This source of this fault is still active
5 = Fault actions cannot have fault actions.
6 = This fault must have a latching mechanism.
7 = Cannot select this Alarm - it is being used by the Hot-Standby feature.
8 = The currently selected reference mode (Radio->Reference->Reference Mode) requires this fault to use
the Reference Switchover fault action.
Latching Mechanism (Stored)
Configured latching mechanism for this fault.
ATI168[a]: Returns the current value of Latching Mechanism.
ATI168[a]=n sets Latching Mechanism to n.
Enumeration values:
0 = None
1 = SW Reset
Where: a = Faults table index (starting from 0).
Can return the following error codes:
1 = Can only reset fault actions.
2 = Cannot latch a fault.
3 = Changing this requires elevated access rights.
4 = Cannot clear. This source of this fault is still active
5 = Fault actions cannot have fault actions.
6 = This fault must have a latching mechanism.
7 = Cannot select this Alarm - it is being used by the Hot-Standby feature.
8 = The currently selected reference mode (Radio->Reference->Reference Mode) requires this fault to use
the Reference Switchover fault action.