User's Manual

Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 94 of 134
Combined Fault Status
The status of the combined alarm.
ATI158: Returns the current value of Combined Fault Status.
Enumeration values:
0 = Inactive
1 = Active
Overview Filter
ATI155: Returns the current value of Overview Filter.
ATI155=n sets Overview Filter to n.
Enumeration values:
0 = Show All
1 = Show Active/Latched
2 = Show Counter > 0
Clear All Faults
Clears all active faults and reverts all fault actions that have been taken.
ATI151: Runs the Clear All Faults routine.
Fault Configuration Menu
Combined Fault Ext. Alarm (Stored)
The hardware alarm associated with the combined alarm.
ATI173: Returns the current value of Combined Fault Ext. Alarm.
ATI173=n sets Combined Fault Ext. Alarm to n.
Enumeration values:
0 = ALM1
1 = ALM2
2 = ALM3
3 = ALM4
4 = ALM5
5 = ALM6
6 = ALM7
7 = ALM8
8 = ALM9
9 = COMB
10 = ALM10
11 = ALM11
12 = ALM12
13 = ALM13
14 = None
Min. Fault Duration (Stored)
The minimum duration a parameter must be in its fault condition before it is reported.
ATI172: Returns the current value of Min. Fault Duration.
ATI172=n[.m].: Sets the value of Min. Fault Duration to n s, given that 0.000 <= n <= 65.535.
Fault Beeper (Stored)
ATI174: Returns the current value of Fault Beeper.
ATI174=n sets Fault Beeper to n.
Enumeration values: