50W Upper Cutoff (Stored)
ATG160[a]: Returns the current value of 50W Upper Cutoff.
ATG160[a]=[+/-]n.: Sets the value of 50W Upper Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
100W Lower Cutoff (Stored)
ATG161[a]: Returns the current value of 100W Lower Cutoff.
ATG161[a]=[+/-]n.: Sets the value of 100W Lower Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
100W Upper Cutoff (Stored)
ATG162[a]: Returns the current value of 100W Upper Cutoff.
ATG162[a]=[+/-]n.: Sets the value of 100W Upper Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
200W Lower Cutoff (Stored)
ATG163[a]: Returns the current value of 200W Lower Cutoff.
ATG163[a]=[+/-]n.: Sets the value of 200W Lower Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
200W Upper Cutoff (Stored)
ATG164[a]: Returns the current value of 200W Upper Cutoff.
ATG164[a]=[+/-]n.: Sets the value of 200W Upper Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
250W Lower Cutoff (Stored)
ATG165[a]: Returns the current value of 250W Lower Cutoff.
ATG165[a]=[+/-]n.: Sets the value of 250W Lower Cutoff to n , given that -2147483648 <= n <=
2147483647.