User's Manual
Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 91 of 134
ATI97[a]: Returns the current value of Hysteresis.
ATI97[a]=n.: Sets the value of Hysteresis to n , given that 0 <= n <= 65535.
Where: a = Status Parameters table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
Lower Cutoff
Lower cutoff value for this sensor. Measurements lower than this cutoff cause a fault.
ATI96[a]: Returns the current value of Lower Cutoff.
Where: a = Status Parameters table index (starting from 0).
Reset Sensor Min/Max
Reset the historical minimum and maximum for this sensor.
ATI181[a]: Runs the Reset Sensor Min/Max routine.
Where: a = Status Parameters table index (starting from 0).
Sensor Interpolation Menu
HW Build Variation Table
Transmit Power Variation Table
Name
Name of the sensor and its unit in this row of the table.
ATG156[a]: Returns the current value of Name.
Where: a = Transmit Power Variation table index (starting from 0).
20W Lower Cutoff (Stored)
ATG157[a]: Returns the current value of 20W Lower Cutoff.
ATG157[a]=[+/-]n.: Sets the value of 20W Lower Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
20W Upper Cutoff (Stored)
ATG158[a]: Returns the current value of 20W Upper Cutoff.
ATG158[a]=[+/-]n.: Sets the value of 20W Upper Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.
50W Lower Cutoff (Stored)
ATG159[a]: Returns the current value of 50W Lower Cutoff.
ATG159[a]=[+/-]n.: Sets the value of 50W Lower Cutoff to n , given that -2147483648 <= n <=
2147483647.
Where: a = Transmit Power Variation table index (starting from 0).
Can return the following error codes:
1 = Invalid cutoff value. Upper cutoff > Lower cutoff
3 = Hysteresis value too large for configured cutoffs.