RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 89 of 134
ATP22=n sets Fan Override to n.
Enumeration values:
0 = Normal
1 = Always On
Sensor To Use (Stored)
Temperature sensor used for fan control.
ATP108: Returns the current value of Sensor To Use.
ATP108=n sets Sensor To Use to n.
Enumeration values:
0 = Baseband Sensor
1 = PA Sensor
2 = Driver Sensor
3 = PA/Driver Ambient Sensor
4 = Isolator Sensor
5 = Baseband Thermistor
6 = PA Group Average
7 = Hottest Sensor
8 = PA Group Sensors
Turn On Temp. (Stored)
Sensed temperature above which fans will be turned on.
ATP20: Returns the current value of Turn On Temp..
ATP20=[+/-]n.: Sets the value of Turn On Temp. to n deg C, given that -128 <= n <= 127.
Turn Off Temp. (Stored)
Sensed temperature below which fans will be turned off.
ATP21: Returns the current value of Turn Off Temp..
ATP21=[+/-]n.: Sets the value of Turn Off Temp. to n deg C, given that -128 <= n <= 127.
Fan Test Interval (Stored)
Interval in hours between fan self-tests.
ATP110: Returns the current value of Fan Test Interval.
ATP110=n.: Sets the value of Fan Test Interval to n hrs, given that 12 <= n <= 48.
Sensors Menu
(Distributer) Fault Reporting (Stored)
ATI213: Returns the current value of Fault Reporting.
ATI213=n sets Fault Reporting to n.
Enumeration values:
0 = Disabled
1 = Enabled
(Distributer) Fail-safes (Stored)
ATI204: Returns the current value of Fail-safes.
ATI204=n sets Fail-safes to n.
Enumeration values:
0 = Disabled
1 = Enabled
Sensor Configuration Menu