ATS230[a]: Returns the current value of Upper Value (Hex).
ATS230[a]=s: Sets the value of Upper Value (Hex) to s, given that 0 <= length(s) <= 32.
Where: a = Key Entry table index (starting from 0).
Can return the following error codes:
1 = Incorrect length - expected 16 characters.
2 = Invalid character(s) - please enter only 0-9 and A-F.
3 = Disable the Key Generator to manually enter keys.
Lower Value (Hex) (Stored)
ATS231[a]: Returns the current value of Lower Value (Hex).
ATS231[a]=s: Sets the value of Lower Value (Hex) to s, given that 0 <= length(s) <= 32.
Where: a = Key Entry table index (starting from 0).
Can return the following error codes:
1 = Incorrect length - expected 16 characters.
2 = Invalid character(s) - please enter only 0-9 and A-F.
3 = Disable the Key Generator to manually enter keys.
Bottom Value (Hex) (Stored)
ATS232[a]: Returns the current value of Bottom Value (Hex).
ATS232[a]=s: Sets the value of Bottom Value (Hex) to s, given that 0 <= length(s) <= 32.
Where: a = Key Entry table index (starting from 0).
Can return the following error codes:
1 = Incorrect length - expected 16 characters.
2 = Invalid character(s) - please enter only 0-9 and A-F.
3 = Disable the Key Generator to manually enter keys.
Encrypted Message Capcode Range Table
Capcodes (Stored)
ATS242[a]: Returns the current value of Capcodes.
ATS242[a]=n.: Sets the value of Capcodes to n , given that 0 <= n <= 2097152.
Where: a = Encrypted Message Capcode Range table index (starting from 0).
Can return the following error codes:
1 = Max cannot be less than Min.
Individual Capcodes Table
Capcodes (Stored)
ATS241[a]: Returns the current value of Capcodes.
ATS241[a]=n.: Sets the value of Capcodes to n , given that 0 <= n <= 2097152.
Where: a = Individual Capcodes table index (starting from 0).
Fan Control Menu
Sensed Temp.
Current temperature at sensor used for fan control.
ATP109: Returns the current value of Sensed Temp..
Time Until Fan Test
ATP111: Returns the current value of Time Until Fan Test.
Fan Override (Stored)
Manual fan override (allows fans to be forced on).
ATP22: Returns the current value of Fan Override.