User's Manual

Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 85 of 134
Duration
The total duration a survey should run for before automatically stopping. A duration of 0 min will run until
the survey is manually stopped.
ATG178: Returns the current value of Duration.
ATG178=n.: Sets the value of Duration to n mins, given that 0 <= n <= 720.
Begin Survey
Starts the survey mode using the settings configured.
ATG180: Runs the Begin Survey routine.
Stop Survey
Stop the survey early or used to stop a survey without a defined duration.
ATG181: Runs the Stop Survey routine.
Send One Message
Send a single message using the settings configured.
ATG182: Runs the Send One Message routine.
Event Menu
Advanced Menu
Custom Deviation (Stored)
The deviation of the custom paging protocol.
ATP103: Returns the current value of Custom Deviation.
ATP103=n[.m].: Sets the value of Custom Deviation to n Hz, given that 0.0 <= n <= 4800.0.
Can return the following error codes:
1 = External data clock required for 4-level protocol
2 = Insufficient access
3 = Warning! External data clock now enabled.
Custom FSK level (Stored)
The FSK-levels of the custom paging protocol.
ATP104: Returns the current value of Custom FSK level.
ATP104=n sets Custom FSK level to n.
Enumeration values:
0 = 2-level
1 = 4-level
Can return the following error codes:
1 = External data clock required for 4-level protocol
2 = Insufficient access
3 = Warning! External data clock now enabled.
Profiles Table
Paging Protocol (Stored)
Configured paging protocol for this profile.
ATP91[a]: Returns the current value of Paging Protocol.
ATP91[a]=n sets Paging Protocol to n.
Enumeration values:
0 = POCSAG
1 = FLEX-2
2 = FLEX-4
3 = Custom