User's Manual
Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 84 of 134
Status
Current status of any in progress survey.
ATG171: Returns the current value of Status.
Enumeration values:
0 = Idle
1 = In Progress
2 = Error: External Encoder
3 = Finished
Message
The message to send during the survey.
ATG172: Returns the current value of Message.
ATG172=s: Sets the value of Message to s, given that 0 <= length(s) <= 30.
Encoding
The character encoding to use.
ATG173: Returns the current value of Encoding.
ATG173=n sets Encoding to n.
Enumeration values:
0 = Alpha-numeric
1 = Numeric
Capcode
The capcode (address) to send the survey messages to.
ATG174: Returns the current value of Capcode.
ATG174=n.: Sets the value of Capcode to n , given that 1 <= n <= 2097152.
Baud Rate
The baud rate of survey messages.
ATG175: Returns the current value of Baud Rate.
ATG175=n sets Baud Rate to n.
Enumeration values:
0 = 512
1 = 1200
2 = 2400
Append
Optionally append timestamp and/or message count to survey messages.
ATG176: Returns the current value of Append.
ATG176=n sets Append to n.
Enumeration values:
0 = Nothing
1 = Count
2 = Timestamp
3 = Count and Timestamp
Interval
The interval in which to send survey messages.
ATG177: Returns the current value of Interval.
ATG177=n.: Sets the value of Interval to n s, given that 1 <= n <= 120.