0 = <CR>
1 = <CR><LF>
Timeout (Stored)
Intercharacter timeout before purging input buffer and reverting to idle state.
ATN16: Returns the current value of Timeout.
ATN16=n[.m].: Sets the value of Timeout to n s, given that 0.5 <= n <= 10.0.
Baud Rate (Stored)
Baud rate at which encoded POSCAG pages are sent over the air.
ATN19: Returns the current value of Baud Rate.
ATN19=n sets Baud Rate to n.
Enumeration values:
0 = 512
1 = 1200
2 = 2400
Stay Logged In (Stored)
Remains logged in indefinitely after receiving a valid login string.
ATN41: Returns the current value of Stay Logged In.
ATN41=n sets Stay Logged In to n.
Enumeration values:
0 = False
1 = True
Implied Login (Stored)
Option to skip login sequence if a <STX> is read while waiting for wake up sequence.
ATN42: Returns the current value of Implied Login.
ATN42=n sets Implied Login to n.
Enumeration values:
0 = Disabled
1 = PG1
2 = PG3
Detect Numeric Pages (Stored)
When enabled, will encode a POCSAG page in numeric format (rather than alpha-numeric) if the message is
wholly formed by digits.
ATN14: Returns the current value of Detect Numeric Pages.
ATN14=n sets Detect Numeric Pages to n.
Enumeration values:
0 = False
1 = True
Group Code (Stored)
Allows the use of the final character or digit in the Pager ID field of a message submission to determine the
function bits of the paging message.
ATN13: Returns the current value of Group Code.
ATN13=n sets Group Code to n.
Enumeration values: