User's Manual
Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 71 of 134
Appendix D. Hayes AT Reference
Note: Not all firmware versions implement all AT commands. For an AT command reference specific to your
firmware version, please contact sales@stiengineering.com.au.
AT-only commands
Print All Sensors
Legacy command for printing all sensor values as a comma separated list.
ATI100: Runs the Print All Sensors routine
Print Faults Mask
Prints a comma separated list of active faults, each fault represented by their index. Prints 'None.' if there are
no faults active.
ATI101: Runs the Print Faults Mask routine
Print Upper Limits
Legacy command for printing all sensor upper cutoff values as a comma separated list.
ATI102: Runs the Print Upper Limits routine
Print Lower Limits
Legacy command for printing all sensor lower cutoff values as a comma separated list.
ATI103: Runs the Print Lower Limits routine
Print Sensor Minimums
Legacy command for printing all sensor minimum recorded values since last sensor history reset as a comma
separated list.
ATI105: Runs the Print Sensor Minimums routine
Print Sensor Maximums
Legacy command for printing all sensor maximum recorded values since last sensor history reset as a
comma separated list.
ATI106: Runs the Print Sensor Maximums routine
Read Faults Detailed
Print all active faults, in the format "<FaultNumber>:<ActiveDuration>:<Counter>, ..."
ATI180: Runs the Read Faults Detailed routine
Online
(Alias for ATO) Exit command parsing mode and go online
ATO0: Runs the Online routine.
Online
Exit command parsing mode and go online
ATO: Runs the Online routine.
Reset
Perform a software reset
AT&T9: Runs the Reset routine.
RUF Init