User's Manual
Configuration
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 23 of 134
3.7.1 Hot Standby
For those RFI-148/RFI-900 that support it (refer to the product order codes in Appendix F), some LIU pins
are re-purposed, as shown in Table 5. The ‘lost’ alarms 11, 12 and 13 are made available when Hot Standby
mode is disabled. Refer also to 7.5.
Pin Number
Direction
Default function
Hot Standby function
4
Output
Alarm 11
PHSB MISSING - External PHSB unit is
missing/not detected
23
Output
Alarm 12
IN STANDBY - The transmitter is waiting for
permission to go active.
24
Output
Alarm 13
IS PRIMARY – this is the primary transmitter
of the redundant pair.
17
Input
LIU detection
CAN GO ACTIVE (HW) – the hardware
means of readying the transmitter for operating
in Hot Standby mode
Table 5:- LIU pin repurposing for Hot Standby support
3.7.2 Analogue Paging
Units that support the Analogue Paging feature repurpose certain LIU pins when this feature is enabled, as
identified in Table 6. When the feature is disabled, these pins are reallocated to their default function. Refer
to 8.2.1 for more information.
Pin Number
Direction
Default function
Analogue function
5
Input
CHAN 4
Audio +
6
Input
CHAN 3
Audio -
13
Input
Aux 1
Analogue/Digital Select
Table 6:- LIU pin repurposing for Analogue Paging support.