User's Manual

Hayes AT Reference
RFI-148 & RFI-900 High Output Power Paging Transmitters User Manual Page 100 of 134
ATP122: Returns the current value of Aux Input 1 Mode.
ATP122=n sets Aux Input 1 Mode to n.
Enumeration values:
0 = Unused
1 = Fault Active Low
2 = Fault Active High
Can return the following error codes:
1 = Cannot configure mode of an unsupported I/O.
Aux Input 2 Mode (Stored)
Controls behaviour of the optional Aux Input 2 on the LIU. Page Active [Low/High] will trigger a Page to
be sent as configured by the [Paging Protocols -> Event] group.
ATP128: Returns the current value of Aux Input 2 Mode.
ATP128=n sets Aux Input 2 Mode to n.
Enumeration values:
0 = Unused
1 = Page Active Low
2 = Page Active High
Can return the following error codes:
1 = Cannot configure mode of an unsupported I/O.
Clock Edge (Stored)
Configures the clock edge to use when using an external data clock.
ATI152: Returns the current value of Clock Edge.
ATI152=n sets Clock Edge to n.
Enumeration values:
0 = Rising-edge
1 = Falling-edge
Can return the following error codes:
1 = Delay must be in increments of 5 us.
2 = Cannot change while transmitting
3 = Warning! External data clock must be used for 4-level protocols
4 = Unsupported with this hardware
Data Invert (Stored)
Set to true to invert data internally before modulation.
ATI153: Returns the current value of Data Invert.
ATI153=n sets Data Invert to n.
Enumeration values:
0 = Normal
1 = Inverted
External I/O Table
Name
ATR248[a]: Returns the current value of Name.
Where: a = External I/O table index (starting from 0).
Direction
ATR249[a]: Returns the current value of Direction.
Enumeration values: