Manual

36
ENGLISH
Remedy
Load new clean Cartridge
Clean chamber
Load new cartridge, inspection
Clean chamber and bolt
Load new cartridge
Wait 1 minute in firing position, unload,
then reload a new cartridge
Wait 1 minute in firing position, unload,
and inspect the rifle. Replacement of the
firing pin by a qualified gunsmith only.
Wait 1 minute in firing position, unload.
Inspection and repairing by a qualified
gunsmith only.
Extractor replaced by a qualified gunsmith
Ejector replaced by a qualified gunsmith
Cause
a) Cartridge not proberly
inserted
b) Chamber fouled
c) Cartridge damaged
a) Chamber or bolt fouled
b) Defective cartridge
Defective cartridge
a) primer punctured: misfire
b) Firing pin defective or
broken (primer not, or
insufficiently punctured)
c) Trigger mechanism
defective
Extractor defective
Ejector fouled or defective
Nature of blockage
Failure to feed cartridge
Bolt cannot be locked
Cartridge did not ignite
Cartridge case is not extracted
Cartridge case is extracted, but
ejected faultily or not at all
No.
1
2
3
4
5