8.2.2. Adjusting the dump valve sensor
1. Stop the conveying cycle by
disconnecting the dump
valve sensor from the
controller. With the dump
valve sensor disabled, no
demand will be indicated,
and conveying will stop.
2. Connect an ohmmeter to
PINS 2 and 3 of the dump
valve sensor.
3. Release the nuts (A) of the
dump valve sensor (B) until
the support can be
displaced.
4. Open the dump valve (C) so far that the front tip of the outlet flap is approx. 1.2” (30
mm) away from the sealing surface.
5. Displace the dump valve sensor (B) until the contact of the magnet switch is closed.
6. Tighten the nuts (A) of the dump valve sensor.
7. Check the adjustment: In case of free hanging dump valve (empty hopper loader) the
contact of the magnet switch must be closed.
8. If the dump valve sensor cannot be properly adjusted, replace the dump valve with
magnet or the sensor.
& Order numbers
Sensor with plug: ID 29570
Dump valve with magnet: ID 28647