User guide

5
Rooftop Packaged Unit
with Evaporative Cooling
Figure 4 - Natural Vent Rooftop Unit with Evaporative Cooler (with Supply Plenum)
A.G.A. C.G.A. GAS INLET
CAPACITY A C D D *F G J L Q R §U NAT LP
10 32-7/8 12 11 20-11/16 19-3/8 31-1/16 24 103-3/8 NA NA 98-1/4 1/2 1/2
(835) (305) (279) (525) (492) (789) (610) (2626) (2496)
15 32-7/8 21-1/2 16 25-3/16 23-1/2 31-1/16 24 103-3/8 NA NA 98-1/4 1/2 1/2
(835) (546) (406) (640) (597) (789) (610) (2626) (2496)
20 43-7/8 23-1/2 16 25-3/16 26-1/4 42-1/16 35 103-3/8 NA NA 98-1/4 1/2 1/2
(1114) (597) (406) (640) (667) (1068) (889) (2626) (2496)
25 43-7/8 23-1/2 16 25-3/16 34-1/2 42-1/16 35 103-3/8 NA NA 98-1/4 3/4 1/2 OR 3/4
(1114) (597) (406) (640) (876) (1068) (889) (2626) (2496)
30 54-7/8 26 17-1/2 26-11/16 37-1/4 53-1/16 46 103-3/8 NA NA 98-1/4 3/4 1/2 OR 3/4
(1394) (660) (445) (678) (946) (1348) (1168) (2626) (2496)
35 54-7/8 26 17-1/2 26-11/16 45-1/2 53-1/16 46 103-3/8 NA NA 98-1/4 3/4 1/2 OR 3/4
(1394) (660) (445) (678) (1156) (1348) (1168) (2626) (2496)
40 60-3/8 26 17-1/2 26-11/16 51 58-9/16 51-1/2 103-3/8 NA NA 98-1/4 3/4 1/2 OR 3/4
(1534) (660) (445) (678) (1295) (1487) (1308) (2626) (2496)
50 43-7/8 23-1/2 16 25-3/16 34-1/2 42-1/16 35 129-5/16 58-3/4 38-5/8 124-1/4 3/4 1/2 OR 3/4
(1114) (597) (406) (640) (876) (1068) (889) (3285) (1492) (981) (3156)
60 54-7/8 26 17-1/2 26-11/16 37-1/4 53-1/16 46 129-5/16 58-3/4 38-5/8 124-1/4 3/4 1/2 OR 3/4
(1394) (660) (445) (678) (946) (1348) (1168) (3285) (1492) (981) (3156)
70 54-7/8 26 17-1/2 26-11/16 45-1/2 53-1/16 46 129-5/16 58-3/4 38-5/8 124-1/4 3/4 1/2 OR 3/4
(1394) (660) (445) (678) (1156) (1348) (1168) (3285) (1492) (981) (3156)
80 60-3/8 26 17-1/2 26-11/16 51 58-9/16 51-1/2 129-5/16 58-3/4 38-5/8 124-1/4 3/4 1/2 OR 3/4
(1534) (660) (445) (678) (1295) (1487) (1308) (3285) (1492) (981) (3156)
NOTE: REFER TO UNIT SUBMITTALS FOR MORE SPECIFICATIONS/UNIT ARRANGEMENTS.
DIMENSIONS ARE IN INCHES, DIMENSIONS IN PARENTHESIS ARE IN MILLIMETERS.
* “F” DIMENSION IS THE RECOMMENDED CLEARANCE TO SERVICE THE BURNER DRAWER(S).
“J” DIMENSION IS AN OUTSIDE DIMENSION FOR RETURN AIR DAMPERS.
“J” DIMENSION IS ALSO AN INSIDE DIMENSION FOR SUPPLY AIR (WITHOUT DAMPER).
§ “U” ALL DIMENSIONS ARE TABULATED FOR ROOFTOP ARRANGEMENTS C & E PER CAPACITIES 10 THROUGH 80 ACCORDINGLY
(CAPACITIES 50/80 ARE SHOWN PICTORIALLY).
NATURAL VENT UNIT DIMENSIONS SHOWN ABOVE; FOR POWER VENT DIMENSIONS, CONTACT CUSTOMER SERVICE FOR POWER
VENT UNIT SUBMITTAL SHEETS.
Table 2B
J Inside
Supply Opening
1-5/16" (33) Typ.
Anchor Hole
Location
5"
(127)
A
C (Typ.) Sq.
*
F
C
L
D
39"
(991)
G
1" (25)
Curb Cap
D4165
T4160CE
5/8" (16) Typ.
Anchor Hole
Location
6-1/16"
(154)
Vent Caps
Are Shipped
In Separate
Cartons
Gas
Connection
6-1/16"
(154)
Evaporative
Cooler
18-7/8" (479)
x J Typ.
Inside
Opening
34-3/4"
(883)
26"
(660)
18-7/8" (479)
x J Typ.
O.S. Damper
Opening
6-1/2"
(165)
3-9/16"
(90)
Lifting
Brackets
Electrical
Connections
Outside
§
R
§
Q
§
L
§
U
26"
(660)
26"
(660)
36"
(914)