Dimensions Guide
60" (1524 mm)
Notes
Required Electrical Service
Measure your actual product for roughing-in
details.
One dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD).
Install this product according to the installation
guide.
120 V, 15 A, 60 HzBlower, Heater:
Blower is supplied with a grounding-type plug-in
cord. Locate the outlet within 24 '' (61 cm) of the
blower.
Technical Information
All product dimensions are nominal.
Drop-inInstallation:
ReversibleDrain location:
Blower service access is required.
44" x 21-1/2" (1118 mm x 546 mm)Basin area, bottom:
Size the drain cutout to fit the drain assembly that
will be used.
51" x 22-3/4" (1295 mm x 578 mm)Basin area, top:
15-1/4" (387 mm)Water depth:
Studs should be positioned roughly as shown.
53 gal (200.6 L)Water capacity:
Blower: 120 V, 9.2 A, 60 Hz
Heater: 300 W
Electrical rating:
USA/Canada: 1-800-STERLING (1-800-783-7546)
www.sterlingplumbing.com
2-14-2015 08:19
Lawson
™
60" x 32" Drop-In Air Massage Bath
77261100