Installation Guide

8. Install the Strike Jamb
Position the latch in the strike jamb as shown.
Using the 5/64 hex wrench provided, tighten the two screws to secure the latch in place.
Repeat with the second latch.
Push the strike jamb into the appropriate wall jamb with the wide lip facing toward the inside of
the shower. Each slot in the strike jamb will slide over the screw body and fit between the clamp
and wall jamb.
Secure the strike jamb to the wall jamb by tightening the flathead screws with the 3/32 hex wrench
until snug.
Install a strike jamb cap on the top opening of the strike jamb.
9. Install the Bulb Seal
Slide the bulb seal strip into the T-slot of the strike jamb until the bulb seal touches the bottom
track.
Cut excess bulb seal away so the seal is flush with the top of the strike jamb.
Wall
Jamb
Strike
Jamb
Strike
Jamb
Latch
#8-18 x 1/2"
Panhead Screw
Bulb Seal
Strike Jamb
Flathead
Screw
Wall Jamb
Adjustment
Clamp
Top View
Strike Jamb Cap
Bottom View
Sterling 9 1019156-2-F