Instruction Manual

Table Of Contents
REVISION 9/04 BJF
67
MAINTENANCE
SECTION 6-8
Cutting Chamber Access
FASTEN THE CUTTING CHAMBE
R
Raise the hold-down clamps to their upright
positions.
Turn the knobs clockwise until they are
tight against the chamber housing.
CLOSE THE CUTTING CHAMBER SAFETY INTERLOCK
Engage the safety interlock by turning the actuator screw clockwise with a box wrench or a ratchet
wrench.
Make sure the screw is fully seated against the surface of its housing.
When engaged, the interlock closes the electrical control circuit to the motor and allows the machine
to run.
RESTART THE GRANULATOR
If necessary to replace the fuses, call an electrician to do it.
UNLOCK AND TURN ON the main power.
Remove the OUT OF SERVICE tag.
Start the granulator by depressing the start push button on the electrical cabinet.