Instruction Manual

Table Of Contents
REVISION 9/04 BJF
52
SETTINGS AND ADJUSTMENTS
SECTION 4-22
Setting The Chamber Jackscrew
WORK SAFELY
TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-
1982 (Lockout/Tag-out of Energy Sources).
If it is not possible to lock out the power, have an electrician remove the fuses.
Make sure the rotor has come to a complete stop.
Wear gloves to protect against injury from the rotor or bed knives.
OPEN THE CUTTING CHAMBER INTERLOCK
Disengage the interlock actuator screw with a box wrench or a ratchet wrench.
Make sure the end of the interlock actuator screw is visible and clear of any contact.
When disengaged, the interlock opens the electrical control circuit to the motor and
prevents the machine from running.