Instruction Manual

Table Of Contents
REVISION 9/04 BJF
27
INSTALLATION
SECTION 3-4
ELECTRICAL WIRING
To wire the granulator, run power (of proper voltage) from the plant source through a lockable, fusible
disconnect to the machine electrical control panel.
50” & 62” machines are equipped with a hydraulic system for opening the hopper.
To wire the hydraulic controls, run power (of proper voltage) from the plant source through a lockable, fusible
disconnect to the machine-mounted control panel.
From the main electrical panel, make the necessary wiring connections to the main drive motor and any
auxiliary motors or control connections.
Refer to the diagram appended to this manual for wiring connections for typical machine applications,
Check the wiring diagram supplied for any wiring that is specific to you application. This diagram is part of the
documentation shipped with the machine.
After power is connected, do not make any adjustments to the machine without performing the
following operations.
TURN POWER OFF and LOCK IT OUT per OSHA 1910.147 or ANSI Z244.1-1982
If you cannot lock out power, have an electrician remove the fuses.
Tag the machine as OUT OF SERVICE.
Make sure the rotor has come to a complete stop.
Wear gloves to protect against injury from the rotor or bed knives.