AccuMeter Controller Chapter 14: The Mass Flow Data Page 91
Chapter 14: The Mass Flow Data Page
This page can be reached by touching the icon for the mass flow hopper from the recipe page.
Blending
Range based
on recipe and
feeder
calibrations
Steady
Window
showing
MEDIAN
p
oint
Weight at
which all
feeders will be
shut off.
Weight at
which all
feeders will run
at the
maximum
b
lendin
g
rate
Access to
active alarms
page
Target/Actual
blender
throuhgput
Inventory of entire
blender. This can be
cleared from the
INVENTORY PAGE.
Indication that
mass flow
weight is in the
steady window
Current weight
of material in
hopper