Instruction Manual

COT-C Series Hot Oil Portable Temperature Control Units Page 33
Figure 4
Control Panel Switches
Pump Rev|Off|Fwd
Turn the Pump Rev|Off|Fwd switch to Fwd to start the pump in
the normal forward direction.
Turn the Pump Rev|Off|Fwd switch to Off to stop the pump and
de-energize the controller.
! CAUTION
Always turn to Pump Off and allow the pump to come
to a complete stop before turning to Pump Reverse.
Failure to let the pump stop before reversing may
damage the pump and drive.
Turn the Pump Rev|Off|Fwd switch to Rev to start the pump in
the reverse direction. Use this feature to purge oil from the mold.
Vent Cycle Start
Press the VENTbutton to start the vent cycle timer. Use this feature
to purge air and water from the unit and process.
Mode Select
With the pump running, you can select the AUTO position or the
Maintained (manual cooling) position with the Mode Select
switch. Select AUTO mode to energize the controller, permitting it
to monitor and control the process. The switch automatically