Owner's manual
Model
96 Standard
Size
075 3/4"
100 1"
150 1-1/2"
200 2"
300 3"
Material
6L 316L
Mark 96 SerieS Sanitary PreSSure regulatorS
orDering schematic
96/0514/AB
Steriflow Valve reserves the right to make revisions to its product, specifications, literature and related information without notice. Please visit our
website at www.steriflowvalve.com for the latest information on our products.
1 Body Finish
A 20Ra (SFV5) Interior/63RMS Exterior (Std)
B 20Ra (SFV5) Interior/20Ra Exterior
C 8Ra Interior/63RMS Exterior*
D 20Ra (SFV5) Interior/8Ra Exterior
E 8Ra Interior/8Ra Exterior*
F 8Ra Interior/20Ra Exterior*
2 Body Cv (Kv) See chart on page 2
Cv Kv
A 1.5 1,3
D 2.5 2,2
H 4.5 3,9
K 5.5 & 6.1 4,7 & 5,3
M 10.0 8,6
N 19.0 16,3
P 23.0 19,8
3 Trim Finish
A 20Ra (Standard)
B 8Ra
4 Trim – Cv (Kv) & Seat
A 1.5 (1,3) Hard Seat N 5.5 (4,7) Jorlon Seat
2 1.5 (1,3) Jorlon Seat P 10 (8,6) Hard Seat
B 2.5 (2,2) Hard Seat Q 10 (8,6) Teon Seat
C 2.5 (2,2) Teon Seat R 10 (8,6) Jorlon Seat
D 2.5 (2,2) Jorlon Seat S 19 (16,3) Hard Seat
H 4.5 (3,9) Hard Seat T 19 (16,3) Teon Seat
J 4.5 (3,9) Teon Seat U 19 (16,3) Jorlon Seat
K 4.5 (3,9) Jorlon Seat V 23 (19,8) Hard Seat
L 5.5 (4,7) Hard Seat W 23 (19,8) Teon Seat
M 5.5 (4,7) Teon Seat X 23 (19,8) Jorlon Seat
7 6.1 (5,3) Hard Seat
5 & 6 O-Ring/Diaphragm
BU Buna-N/SST Diaphragm
EE EPDM/EPDM Diaphragm
EP EPDM/SST Diaphragm
SL Silicone/SST Diaphragm
TS
Teon Encaps. Silicone/SST Diaphragm
(1-1/2" - 3" only)
TY Teon Encaps. Viton/Jorlon Diaphragm
TV Teon Encaps. Viton/SST Diaphragm
VT Viton/SST Diaphragm
8 Range PSI (Bar) see chart on page 2
A 3 - 8 (0,2 - 0,6)*
C 5 - 25 (0,3 - 1,7)
E 10 - 25 (0,7 - 1,7)
P 15 - 25 (1,0 - 1,7)
H 15 - 50 (1,0 - 3,4)
J 15 - 60 (1,0 - 4,1)
M 35 - 100 (2,4 - 6,9)
R 40 - 90 (2,8 - 6,2)
T 75 - 135 (5,2 - 9,3)
7 Adjusting Screw Finish (Except Threads)
A Electro-polished (Standard)
B 20Ra (SFV5)
C 8Ra
9 & 10 Diaphragm
6L SST (all exterior)
EP EPDM (all exterior)
JL Jorlon (all exterior)
UJ Ultra-thin Jorlon (all exterior)
11 & 12 Actuator Finish/Type
AA Standard
BA 20Ra (SFV5) exterior
CA 8Ra exterior
DA Electro-polished for 2" & 3"
* Handle and all external surfaces meet spec per above. The adjust-
ing screw is a threaded part and cannot be polished beyond 20Ra
Body Conguration
Leave blank for standard
90 3/4" Tri-Clamp F/Gauge @ 90°
180 3/4" Tri-Clamp F/Gauge @ 180°
270 3/4" Tri-Clamp F/Gauge @ 270°
* Must use EPDM or Ultra-thin Jorlon diaphragm
— — —
1
1 & 2 3 & 4 5 & 6 7 & 8 9 & 10 11 & 12 13 & 14
13 & 14 PED Compliance
00 Not required
FF CE Category 1
ZZ Non-standard