Owner manual

JSRLP SeRieS HigH PuRity Bio-PHaRma gaS Low PReSSuRe Reducing VaLVe
Flow Data For cV trim selection
-4-
The graphs illustrate the change or "droop" in outlet pressures as the flow rate increases, and the lockup (setpoint rise) as flow
decreases and approaches zero.
Flow Coefficient: 0.5
Maximum inlet pressure: 150 psig (10,3 bar)
Pressure Control Range
Range Spring: 0-75 psig (0-5,2 bar)
Set Point: 1 psig
Pressure Control Range
Range Spring: 0-75 psig (0-5,2 bar)
Set Point: 2 psig