PRODUCT DESCRIPTION
°STELPRO universal heating cable is designed to heat a room with a heating cable placed under your oor covering. It can heat oor covering
materials such as marble, ceramic and porcelain tiles, slate, granite as well as some poured surfaces. Before using this oor heating system under
any other type of oor covering, contact your oor covering manufacturer to nd out whether it’s appropriate for this type of installation.
°STELPRO universal heating cable is designed for installation in membranes or with cable spacers (supplied with the product).
This product is designed for indoor use on a concrete slab or plywood embedded in thin-set or self-leveling mortar. °STELPRO universal heating
cable must be installed on a circuit that has a ground-fault GFCI circuit interrupter.
In Canada only: Heating cable can be installed under a shower oor covering that has a cement base poured on site. In such cases, the cable
should be installed under the membrane and within the cement base. In the United States, installing a heating cable under a shower isn’t permitted.
TECHNICAL DESCRIPTION
The heating cable is comprised of two twisted conductors with uoropolymer primary insulation. The primary insulation is protected with a tin cop-
per wire and an external PVC sheath. The heating cable has a 7-foot cold cable.
TECHNICAL SPECIFICATIONS
DESCRIPTION SCU
Voltage 120 V, 208/240 V
Spacing 3 spaces or 4 spaces
Linear density 3.8 W/ft
Surface density 12 W/ft2 (3 spaces) / 9 W/ft2 (4 spaces)
Surface coverage 13 - 279 ft2 (3 spaces) / 16 - 366 ft2 (4 spaces)
Cold cable length 7 ft
Cold cable diameter 3/16” x 3/8”
Cold cable gauge 14AWG (3 wires)
Hot cable diameter 0.180”
Min. folding radius 0.5”
Insulation resistance Fluoropolymer (ECTFE)
External sheath PVC
Ground Tin copper wire
Max. operating temperature 105°C
Min. installation temperature 5°C
Certication cCSAus
Marking WS, X