User Guide
5
INSSIL20300416
2
3
7
4
5
1
6
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the
“Limited warranty” section to obtain the phone numbers).
The unit does not work
• Defective thermostat/timer or wrong thermostat/timer setting
• Open circuit breaker or fuse
• The thermal protection has been activated
• Faulty connections
The unit runs continuously
• Defective thermostat/timer or wrong thermostat/timer setting
• Heat losses higher than the unit capacity
The enclosure is extremely hot
• Defective thermal protection
• Blocked air vents
• Defective motor
The unit cycles under control of the thermal protection (overheat
indicator)
• Blocked air vents
• Defective motor
Overheating
• Defective thermostat/timer or wrong thermostat/timer setting
• Defective motor
The breaker trips when the heater is turned on
• Faulty connections
• Voltage higher than that written on the nameplate
Elements are on, but the motor does not work • Defective motor
The desired room temperature cannot be reached
• One or more elements are defective
• Defective thermostat/timer or wrong thermostat/timer setting
• Voltage lower than that written on the nameplate
• Heat losses higher than the unit capacity
1 BOUT-250 THERMOSTAT/TIMER KNOB (WHITE)
1 BOUT-250-A THERMOSTAT/TIMER KNOB (ALMOND)
2 ELF-250 INTEGRATED ELEMENT PROTECTION
3 MO-250 MOTOR/FAN (240V)
4 M-SIL203000C1 TOP GRILL
5 M-SIL203003Z1 FRONT COVER
6 ST-017 THERMOSTAT SP
7 TIM-250 TIMER 30 MIN.
TROUBLESHOOTING
REPLACEMENT COMPONENT LIST