The unit does not work
Defective thermostat/timer or wrong thermostat/timer setting
Open circuit breaker or fuse
The thermal protection has been activated
Faulty connections
The unit runs continuously
Defective thermostat/timer or wrong thermostat/timer setting
Heat losses higher than the unit capacity
The enclosure is extremely hot
Defective thermal protection
Blocked air vents
Defective motor
The unit cycles under control of the thermal protection (overheat
indicator)
Blocked air vents
Defective motor
Overheating
Defective thermostat/timer or wrong thermostat/timer setting
Defective motor
The breaker trips when the heater is turned on
Faulty connections
Voltage higher than that written on the nameplate
Elements are on, but the motor does not work Defective motor
The desired room temperature cannot be reached
One or more elements are defective
Defective thermostat/timer or wrong thermostat/timer setting
Voltage lower than that written on the nameplate
Heat losses higher than the unit capacity
  
1 BOUT-250 THERMOSTAT/TIMER KNOB (WHITE)
1 BOUT-250-A THERMOSTAT/TIMER KNOB (ALMOND)
2 ELF-250 INTEGRATED ELEMENT PROTECTION
3 MO-250 MOTOR/FAN (240V)
4 M-SIL203000C1 TOP GRILL
5 M-SIL203003Z1 FRONT COVER
6 ST-017 THERMOSTAT SP
7 TIM-250 TIMER 30 MIN.
TROUBLESHOOTING
REPLACEMENT COMPONENT LIST