The bottom of this unit must be installed at least 4 inches (10.2 cm) from the oor and 6 inches (15.2 cm) from any adjacent surfaces. However, make
sure objects or pieces of furniture such as, but not limited to, blankets, towels, beds, laundry baskets, clothing, papers, etc. do not come into contact with the
unit and keep them at least 12 inches (30.5 cm) from the unit since they are more ammable than walls and oors. Failure to comply with this warning
could lead to a re. Some materials are more heat-sensitive than others, so make sure those near the unit can withstand heat.
Do not install on a wall behind a door.
Do not paint the unit.
Never block air vents. This obstruction could lead to overheating, which could result in a re.
Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, a re or damages to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing ammable liquids, combustible materials
or corrosive, abrasive, chemical, explosive and ammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning products.
Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on
and inside air vents. Accumulated dirt can lead to a component malfunction or give a yellowish colour to unit. Failure to install and maintain unit in accordance
with these instructions poses a re hasard.
Thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or
activates and deactivates repeatedly, it is recommended that a qualied electrician or a certied repair centre examine the unit in order to make sure it is not
damaged. (Refer to the limited warranty.)
If the unit is damaged or defective, cut off power supply at circuit breaker and call a certied repair centre. (Refer to the limited warranty) If the unit is damaged
or defective, cut off power supply at circuit breaker and call a certied repair centre. (Refer to the limited warranty.)
WARNING
Note: When a part of the product specication must be changed to improve operability or other functions, priority is given to the product specication itself. In such
instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and
illustration, may differ from the manual. The screen/LCD display shown as an example in this manual may be different from the actual screen/LCD display.
SPECIFICATIONS
SPECIFICATIONS
BUILT-IN
THERMOSTAT
WITHOUT
THERMOSTAT
POWER VOLTAGE HEIGHT LENGTH WEIGHT
CODE CODE WATTS VOLTS MM IN. MM IN. KG LB
MIR0501 MIR0501WC 500 120 457 18 444 17 1/2 5.1 11.2
MIR0508 MIR0508WC 500 208 457 18 444 17 1/2 5.1 11.2
MIR0502 MIR0502WC 500/375 240/208 457 18 444 17 1/2 5.1 11.2
--- MIR0507WC 500 277 457 18 444 17 1/2 5.1 11.2
--- MIR0503WC 500 347 457 18 444 17 1/2 5.1 11.2
MIR1001 MIR1001WC 1000 120 457 18 597 23 1/2 6.0 13.3
MIR1008 MIR1008WC 1000 208 457 18 597 23 1/2 6.0 13.3
MIR1002 MIR1002WC 1000/750 240/208 457 18 597 23 1/2 6.0 13.3
--- MIR1007WC 1000 277 457 18 597 23 1/2 6.0 13.3
--- MIR1003WC 1000 347 457 18 597 23 1/2 6.0 13.3
--- MIR1005WC 1000 480 457 18 597 23 1/2 6.0 13.3
--- MIR1006WC 1000 600 457 18 597 23 1/2 6.0 13.3
MIR1501 MIR1501WC 1500 120 457 18 749 29 1/2 7.1 15.7
MIR1508 MIR1508WC 1500 208 457 18 749 29 1/2 7.1 15.7
MIR1502 MIR1502WC 1500/1125 240/208 457 18 749 29 1/2 7.1 15.7
--- MIR1507WC 1500 277 457 18 749 29 1/2 7.1 15.7
--- MIR1503WC 1500 347 457 18 749 29 1/2 7.1 15.7
--- MIR1505WC 1500 480 457 18 749 29 1/2 7.1 15.7
--- MIR1506WC 1500 600 457 18 749 29 1/2 7.1 15.7
MIR2008 MIR2008WC 2000 208 457 18 902 35 1/2 8.6 18.9
MIR2002 MIR2002WC 2000/1500 240/208 457 18 902 35 1/2 8.6 18.9
--- MIR2007WC 2000 277 457 18 902 35 1/2 8.6 18.9
--- MIR2003WC 2000 347 457 18 902 35 1/2 8.6 18.9
--- MIR2005WC 2000 480 457 18 902 35 1/2 8.6 18.9
--- MIR2006WC 2000 600 457 18 902 35 1/2 8.6 18.9
Add W for white, SW for silica white and SS for stainless steel
BUILT-IN THERMOSTAT POWER VOLTAGE HEIGHT LENGTH WEIGHT
CODE WATTS VOLTS MM IN. MM IN. KG LB
MIR1501PW 1500 120 457 18 749 29 1/2 7.1 15.7