Use and Care Manual
6
INSSORB1017
BUTTON CONTOUR COLOURS
BUTTON CONTOUR COLOURS STATUS OF UNIT
GREEN Normal operation, economical temperature setpoint
BETWEEN GREEN AND RED
Normal operation, the color reflects how economical the temperature setpoint is; more green is
more economical and more red is less economical
RED Normal operation, high temperature setpoint
FLASHING BLUE Open window detected
WHITE While in advanced menus
GRAY When the backlighting is set to off and the buttons remain inactive for more than 15 seconds
BOOST BUTTON RED Boost mode activated
The supply wires must be connected in accordance with all codes in effect. Connect the bare wire (ground) to the unit’s ground screw (green).
Connect wires from the electrical box to the unit’s supply leads.
N.B. This product must be connected by a qualied electrician according to electrical and building codes in effect in your region.
FIXED CONNECTION MODELS:
GND
Fuse linkThermal protection
Element
Motor
Disconnect switch
(optional)
Electronic thermostat
(optional)
L1
L2/
N
ELECTRICAL WIRING
°STELPRO MENU
Information about the unit is available in the advanced menus.
Follow these steps to access this information:
- Access the advanced menus.
- Select menu 7.
- Select one of the following sub-menus:
• 7.1: Version of convector
• 7.2: Version of Zigbee Radio
• 7.3: Day manufactured
• 7.4: Month manufactured
• 7.5: Year manufactured
• 7.6: Internal control code
• 7.7: Factory reset of convector
UNIT OVERHEAT DETECTION
This unit can detect when it is overheating.
If your unit’s thermal protection gets activated, an
icon will ash on
the display.
FACTORY RESET
Follow these steps to reset the convector to its factory settings:
- Access the advanced menus.
- Select menu 7.
- Select sub-menu 7.7 and select YES.
- Conrm the selection.
- YES will ash for few seconds, and the convector will be reset to its
factory settings.