Specifications
1312
GB
Functional warranty
This Steinel product has been
manufactured with great care,
tested for proper operation
and safety in accordance with
applicable regulations and
then subjected to random
sample inspection. STEINEL
guarantees that it is in perfect
condition and proper work-
ing order.
The warranty period is 36
months, starting on the date
of sale to the consumer. We
will remedy defects caused by
material flaws or manufactur-
ing faults. The warranty will be
met by repair or replacement
of defective parts at our own
discretion.
The warranty does not cover
damage to wear parts, dam-
age or defects caused by
improper treatment or main-
tenance.
Further consequential dam-
age to other objects shall be
excluded.
Claims under the warranty will
only be accepted if the unit is
sent fully assembled and well
packed with a brief descrip-
tion of the fault, a receipt or
invoice (date of purchase and
dealer's stamp) to the appro-
priate Service Centre.
Repair Service:
Our Customer Service Depart-
ment will repair faults not
covered by warranty or occur-
ring after the warranty period
has expired. Please send the
product well packed to your
nearest Service Centre.
Troubleshooting
Declaration of conformity
Malfunction
SensorLight without power
SensorLight will not switch
"ON"
SensorLight will not switch
"OFF"
■ Fuse faulty, not switched
"ON", break in wiring
■
Short circuit
■ Twilight control set to
night-time mode during
daytime operation
■
Bulb faulty
■
Mains switch "OFF"
■
Fuse faulty
■ D
etection zone not prop-
erly targeted
■
Internal electrical fuse
has been activated
■
Re-set
■
Change bulb
■
Switch "ON"
■
Renew fuse, check con-
nection if necessary
■R
e-adjust
■
Switch SensorLight
"OFF" and "ON" again.
■
Continued movement in
detection zone
■ Check detection zone
and re-adjust if necessary
SensorLight keeps switch-
ing "ON/OFF"
■
Animals moving in detec-
tion zone
■
Tilt sensor up; change
zone
SensorLight switching "ON"
when it should not
Change in SensorLight reach
This product complies
with Low Voltage Directive
06/95/EC, EMC Direc-
tive 04/108/EC and RoHS
Directive 02/95/EC.
■ Wind is moving trees and
bushes in the detection
zone
■
Cars in the street are
being detected
■
Sunlight shining on the
lens
■
Reflection from bright
building walls or light-
coloured floor covering
■
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans or
open windows
■
Differing ambient tem-
peratures
■
Change zone
■
Change detection zone,
tilt sensor down
■ Mount sensor in a pro-
tected place or change
zone
■
Re-adjust twilight setting
■
Adjust detection zone or
change site of installation
■ When it is cold, shorten
reach by tilting sensor
down
■
When it is hot, tilt sensor
up
■
New fuse; switch on
mains switch; check wir-
ing with voltage tester
■
Check connections
Cause Remedy