assembly Instructions

Advanced Configuration
For more detailed information, please download the profes-
sional instructions from z-wave�steinel�de.
A� Description of device endpoints:
The functionality of the device is divided to endpoints by
their using.
0 = ROOT
To root summarizes whole device function, to root endpoint is
mapped all functionality from the endpoint 1 and most of the
endpoints 2 and 3.
Device type = On/O Power Switch
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_VERSION ( v2 )
COMMAND_CLASS_FIRMWARE_UPDATE_MD ( v3 )
COMMAND_CLASS_MANUFACTURER_SPECIFIC ( v2 )
COMMAND_CLASS_MULTI_CHANNEL ( v4 )
COMMAND_CLASS_DEVICE_RESET_LOCALLY ( v1 )
COMMAND_CLASS_CONFIGURATION ( v1 )
COMMAND_CLASS_POWERLEVEL ( v1 )
COMMAND_CLASS_NODE_NAMING ( v1 )
COMMAND_CLASS_NOTIFICATION ( v4 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SWITCH_BINARY ( v1 )
COMMAND_CLASS_SCENE_ACTIVATION ( v1 )
COMMAND_CLASS_SCENE_ACTUATOR_CONF ( v1 )
COMMAND_CLASS_SWITCH_ALL ( v1 )
COMMAND_CLASS_APPLICATION_STATUS ( v1 )
COMMAND_CLASS_SENSOR_MULTILEVEL ( v4 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
1 = LAMP
To endpoint 1 is mapped basic lamp functionality.
Device type = On/O Power Switch
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SWITCH_BINARY ( v1 )
COMMAND_CLASS_SCENE_ACTIVATION ( v1 )
COMMAND_CLASS_SCENE_ACTUATOR_CONF ( v1 )
COMMAND_CLASS_SWITCH_ALL ( v1 )
COMMAND_CLASS_APPLICATION_STATUS ( v1 )
Controlled Command Classes:
No
2 = MOTION SENSOR
To endpoint 2 is mapped motion sensor (PIR) functionality.
Device type = Sensor - Notification
Supported Command Classes:
COMMAND_CL ASS _Z WAVEPLUS_INFO ( v2 )
COMMAND_CL ASS _BASIC ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CL ASS _NOTIFICATION ( v4 )
COMMAND_CLASS_MULTI_CHANNEL_ ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
Controlled Command Classes:
COMMAND_CL ASS _BASIC ( v1 )
Special meaning of BASIC CC:
BASIC CC can activate/temporary deactivate internal motion
sensor using for evaluating the behaviour of the lamp and
groups 2 and 3. Events are, however, still transmitted to the
Lifeline, and the device can be controlled via remote motion
sensors (please also follow the configuration parameter 16).
Basic Set: active ( 0xFF ) / inactive ( 0x00 ) sensor function
Basic Get: get sensor activity
Basic Report: sensor activity status
3 = AMBIENT LIGHT SENSOR
To endpoint 3 is mapped ambient light sensor ( lumines-
cence sensor synchronized with lamp ) functionality.
Device type = Sensor - Multilevel
Supported Command Classes:
COMMAND_CLASS_ ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_ SENSOR_ MULTILEV EL ( v4 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
Controlled Command Classes:
No
B� Description of association groups:
0 = ROOT DEVICE
Group 1 – "Lifeline" – only 1 node
Lifeline messages
- Device Reset Locally
- Notifications:
0x09 ( System ) – Hardware failure with manufacturer
proprietar y code ( 0x03 )
0x09 ( System ) – Software failure with manufacturer
proprietary code ( 0x04 )
0x07 ( Home security ) – Motion Begin event ( 0x08 )
0x07 ( Home security ) – Motion End event ( 0x00, 0x08 )
- Binary Switch Report – lamp state
- Multilevel Sensor Report – value of internal ambient light
sensor
Motion Begin and Motion End events are sent along with
frames to group 3. If multichannel association is created the
events are sent from motion sensor endpoint.
Switch Report is sent immediately upon a change of status
along with frames to group 2. If multichannel association is
created the events are sent from lamp endpoint.
Multilevel Sensor Report is sent a maximum of once per
1minute (if the value has changed by least by 3%) and
a minimum of once per 15 minutes (if the value has not
changed). If the ambient light value is old (cannot measure
because of permanent light), the value is not transmitted via
lifeline. Multilevel Sensor Report can be also added to some
other events to send in bulk. If multichannel association is
created the events are sent from light sensor endpoint.
All notifications to lifeline are sent as sensor states regard-
less of sensor settings and states as SLAVE_MODE,
LOCAL_DISABLED and MOTION_ENABLE.
Group 2 – "On/O control" – max 16 nodes
Group 2 is used for directly controlling Z-Wave devices via
BASIC SET commands through the evaluation of movement
and light as with internal use ( so that all of these devices work
together ). This is intended for use especially with third-party
devices that do not implement reactions for motion events.
BASIC_SET and similar Z-Wave commands are not retrans-
mitted intentionally to slaves and must be sent to slave devic-
es via the controlling device simultaneously. Only for use in
master-slave system, multidevice control is not possible.
– 32 –
– 33 –
Guasto Causa Rimedio
Il faro LED a sensore è senza
tensione
Fusibile difettoso, lampada
non accesa, punto di interru-
zione nel cavo
Corto circuito
Sostituite il fusibile, accendete
l'interruttore, controllate la linea di
alimentazione con un voltmetro
Controllate gli allacciamenti
Il faro LED a sensore non si
accende
Nel funzionamento con luce
diurna l'impostazione crepu-
scolare è regolata sul funzio-
namento di notte
Interruttore di rete su OFF
Fusibile difettoso
Campo di rilevamento non
impostato in modo mirato
Eseguite una nuova impostazione
Accendete
Cambiate fusibile, eventualmente
controllate l'allacciamento
Eseguite una nuova regolazione
Il faro LED a sensore non si
spegne
Movimento continuo nel
campo di rilevamento
Controllate il campo di rilevamen-
to, eseguite eventualmente una
nuova regolazione o una scher-
matura
Il faro LED a sensore si accende
e spegne in continuazione
Animali in movimento nel
campo di rilevamento
Orientate il sensore più in alto o
copritelo in modo mirato, spostate
o coprite il campo di rilevamento
Il faro LED a sensore interviene a
sproposito
Vento che muove alberi e
cespugli all'interno del campo
di rilevamento
Vengono rilevate automobili
sulla strada
Improvvisi sbalzi di temperatu-
ra dovuti a condizioni atmosfe-
riche (vento, pioggia, neve) o
causati da aria di scarico di
ventilatori o da aria provenien-
te da finestre aperte
Il faro LED a sensore oscilla
(si muove) per es. in seguito a
rache di vento o a forti
precipitazioni
Spostate il campo
Spostate il campo
Modificate il campo o spostate il
luogo di montaggio
Montate il faro LED a sensore su
una base stabile
Non è possibile aggiungere
l'apparecchio (l'apparecchio non
è stato ancora aggiunto)
Distanza eccessiva tra
controller Z-Wave e
apparecchio
Riducete la distanza dal controller
Z-Wave
Montate un ripetitore Z-Wave
Non è possibile aggiungere
l'apparecchio
È già stato aggiunto Rimuovete l'apparecchio dalla
rete esistente
Eseguite il default reset
Il LED di stato
lampeggia
ogni 5 secondi per 1 secondo
Nessun contatto radio con la
Smart Friends Box o altri
controller Z-Wave
Riavviate la Smart Friends Box o
il controller Z-Wave
Riducete la distanza dal controller
Z-Wave
Montaggio di un ripetitore
Z-Wave
Il LED di stato
lampeggia
rapidamente e permanentemen-
te
Errore critico Staccate per breve tempo
l'apparecchio dalla tensione di
rete
12� Disturbi di funzionamento