Instructions

15
Product parts (Fig.3.5, 3.6 )
A LED light
B Clip
C Connecting terminal
D Wall mount
E Sensor unit (only S)
F Time setting (only S)
G Twilight setting (only S)
H Programme setting (only S)
Luminous intensity distribution
(Abb.3.7)
Wiring diagram (Fig.3.8)
The supply lead is a three-core cable:
L = phase conductor (usually black,
brown or grey)
N = neutral conductor (usually blue)
= protective-earth conductor
(green/yellow)
A mains switch for switching the product
ON and OFF may be installed in the
mains supply lead.
Important: The light source of this
luminaire is not replaceable; if the light
source needs to be replaced (e.g. at
the end of its life), replace the complete
luminaire.
Technical specifications
Dimensions (H×W×D):
260×78×131mm
Power supply: 220 - 240V, 50/60Hz
Power consumption (P
on
): 11.3W
Standby (P
sb
) (Sensor):
L605 S: 0.50W
Luminous flux: 729lm
Eciency: 64.5lm/W
Light temperature:
3,000K (warm white)
Colour-rendering index: R
a
=82
Rated average lifetime:
L70B50 at 25°C: 36,000 hrs
Colourconsistency SDCM:
Initial value: 6
Luminous intensity distribution:
LumEdit
202101051244_L605.ldt
Polar Diagram
08.03.21 / 11:02 1/1
20
40
60
80
100
90°90°
180°
30°30°
150°150°
60°
120°
60°
120°
cd / 1000 lm
C0 / C180 C90 / C270
Sensor technology:
L605 S: passive infrared
Angle of coverage: L605 S: 180°
Detection reach:
L605 S: 10m tangential
Mounting height: 2m
Twilight setting:
L605 S: 10 - 2,000lux
Night light: L605 S: 10%
Time setting: L605 S: 5sec - 15min
Ambient temperature: -10°C to +40°C
IP rating: IP44
Protection class: I
Energy eciency class:
This product contains a light source
of energy eciency class „E“.
4. Installation
Hazard from electrical power.
Touching live parts can result in electrical
shock, burns or death.
Switch OFF power and interrupt
power supply.