assembly Instructions

- 56 -
Sequency timing:
Parameter Number Size Range Default
15 ( SEQUENCY_TIME ) 1 10 – 50 10
Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC
OFF (and vice versa) to relay endpoint to consider this as a sequence. It is
typically 1 second, but can be exceptionally longer due to retransmissions and
overload – in this case, a longer interval can be allowed (up to 5 seconds).
Motion O behaviour (timeout):
Parameter Number Size Range Default
16 (MOTION_DISABLE) 2 0 – 209, 255 0
Motion disable timeout after BASIC SET to motion endpoint when the internal
motion sensor is not used for evaluating the behaviour of the relay and groups
2 and 3. Events are, however, still transmitted to the Lifeline, and the relay can
be controlled via remote motion sensors.
0
BASIC SET to Motion sensor endpoint ignored, BASIC to root is
mapped to relay endpoint, motion sensor still enabled
1 -209
Internal motion sensor is disabled for specified timeout after BASIC
SET 0x00 to Mootion sensor endpoint. BASIC to root is mapped to
Motion sensor endpoint.
Timeout:
1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution
101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution
201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution
210-254 Reserve
255
BASIC SET to Motion sensor endpoint ignored, BASIC to root is
mapped to relay endpoint, motion sensor still disabled