assembly Instructions
- 52 - - 53 -
C� Configuration description:
Time [ s ]:
Parameter Number  Size Range Default
1 ( TIME ) 2 5-900 180
Duration of light after motion detection.
Light threshold [lx]:
Parameter Number  Size Range Default
2 ( LIGHT ) 2 2-2000, 0 2000/poti state 
0 – run Learn ambient light sequence.
2000 - is used as daylight ( always night mode ). 
Value can be controlled via potentiometer – potentiometer value is used as the 
default value and any potentiometer movement rewrites the current setting.
Motion Sensor (PIR) Sensitivity [%]:
Parameter Number  Size Range Default
5 ( SENSITIVITY ) 1 2-100 100
Value can be controlled via potentiometer – potentiometer value is used as the 
default value and any potentiometer movement rewrites the current setting.
Brightness measuring interval [ minutes ]:
Parameter Number  Size Range Default
6 ( BRIGHTNES MEAS INTERVAL ) 1 5-120, 0 0
Interval for ambient light measuring when lamp is on ( lamp switches o shortly 
and measures ). 0 = function is o.
Use External Ambient Light Value:
Parameter Number  Size Range Default
8  ( GLOBAL_LIGHT ) 1 0/1 1
When GLOBAL_LIGHT mode is ON – device overrides its own light sensor 
values and uses Light report values from any Z-Wave light sensor instead – 
this has to be configured appropriately to send light automatically.
If the last remote light level value is older than 30 minutes, the internal light 
value is used again until the next external value is received.
Disable local control:
Parameter Number  Size Range Default
9  ( SLAVE_MODE ) 1 0-4 2
Bit Field:
bit 7 6 5 4 3 2 1 0
function - - - - -
"Stupid" 
mode
Central unit 
checking in 
slave mode
Slave 
mode
"Stupid" mode ( bit 2 = 1 ):
  - has higher priority then slave mode.
  - lamp is permanently on ( usefull for simple power wall switch controlling ).
Slave mode ( bit 0 = 1 ):
  - only if included in Z-Wave network
  - usefull for controlling via third-party sensor
  - lamp is directly controlled via Z-Wave, internal sensors are not used for 
controlling it.
Central unit checking ( bit 1 = 1 ):  
( usefull especialy for controlling via gateway )
  When Slave bit is 0:
  - lamp signalises fail of lifeline connection ( if this bit is zero fail of lifeline 
connection is not signalised )
  When slave bit is 1:
  - lamp checks presence of Z-Wave device in lifeline group ( gateway ). If it is 
not present for 2minutes ( testing repeatedly every 30seconds ) device 
switches to normal mode in the same way as after the end of local disabled 
mode  ( ON_BEHAVIOUR )
  - The device checks every 1minute for recovery of Lifeline connection.
  - if no lifeline specified - it works in normal mode
Be careful with this option, lamp stops using it’s own motion sensor in 
Slave and Stupid mode.
O behavior  ( timeout ):
Parameter Number  Size Range Default
10 ( OFF_BEHAVIOUR ) 2 0 – 209,255 10
Behaviour after BASIC OFF ( and similar commands ).










