PROFESSIONAL
HOT MELT SYSTEM
• Drawer assembly
• Face frames
• Miter joints
• No clamp glue-ups
• Crown/trim molding
• Cabinet assembly
• Ornamental fixtures
• Window/door casings
• Furniture repair
• Maintenance repair
• Countertop backsplash
Outdoor furniture assembly
User Tips
Make sure the adhesive is fresh. All HiPURformer™ adhesives have a
one-year shelf life in the unopened foil pouch. Take note of the
expiration date, as marked on the top portion of the foil pouch.
Each new adhesive cartridge MUST be heated for at least 12 minutes.
(The green light will remain on temporarily if the heat cylinder is hot
from previous use.)
First time users should practice applying the adhesive on scrap
materials to better understand product performance characteristics.
When finished using the adhesive, take the necessary precautions to
prolong the shelf life to a minimum of four weeks.
Extrude a one-inch bead of adhesive to ensure there is no air in
the cartridge tip
Replace the cartridge cap tightly while the adhesive is hot
Do not allow the cartridge/adhesive to continually heat without use for
more than 17 hours at a time.
While the HiPURformer™ adhesives provide waterproof bonds, this
product is not designed for applications below the waterline or for
continuous submersion.
Clean-Up
Who should be contacted in the event of a medical emergency?
For emergencies, contact Chemtrec at 800-424-9300 or Chemtrec
International at 703-527-3887. For additional information, contact
Franklin security at 614-445-1300.
How do I get the adhesive off my hands?
We strongly recommend that you wear gloves when using
HiPURformer™ polyurethane hot melt adhesives. However, if you do
get the adhesive on your skin, wash thoroughly with soap or a pumice
cleanser. Repeated washings may be necessary.
How long does it take to heat the adhesive to working temperature?
It takes approximately 10 – 13 minutes for the adhesive to become
liquid. It may appear to be thicker than traditional glues you may have
used, but the product will flow nicely out of the cartridge.
How long can I work until I need to recharge?
After the material has heated to the working temperature, you will have
approximately 20 minutes of "cordless" gluing. When it appears that
the adhesive is becoming too thick to be extruded from the cartridge,
slide the adhesive applicator back into the charger.
Basic safety precautions should always be followed to
reduce the risk of personal injury. For detailed
procedures, read the instruction manual packaged
with the HiPURformer™ Adhesive Applicator.
Always wear gloves when working with
the HiPURformer™, as the
adhesive and heat cylinder
become extremely hot.
Do not touch
exposed adhesive
until it has
hardened.
Allow any excess adhesive to become firm (it turns from clear to
opaque). This adhesive can be easily scraped off of the surface with a
putty knife. Fully cured adhesive must be removed with a chisel,
scraper, or sandpaper.
If adhesive gets on your skin, use soap or hand cleaner to remove. If
unsuccessful, common solvents (rubbing alcohol) may be used.
FAQs
What makes HiPURformer™ polyurethane hot melt adhesive stronger
than conventional hot melts?
HiPURformer™ polyurethane hot melts form an initial bond
immediately upon cooling, similar to conventional hot melts.
Additionally, PUR’s offer a second phase where the adhesive reacts
with moisture to form an extremely strong chemically cross-linked
bond. At this point, the adhesive actually penetrates the substrate and
makes a strong chain, producing a strong, permanent bond.
Will the adhesives foam as they cure?
No. The foaming associated with pourable polyurethane glues will not
occur with polyurethane reactive hot melts. You may experience
squeeze-out similar to other glues, which can easily be removed from
the surface.
How much time does the cross-linking reaction take?
The cross-linking reaction takes place over a period of time ranging
from hours to days and bond strength builds proportionately. The
initial bond has enough strength to allow assemblies to be machined
or finished immediately after the ahesive has set. Load bearing joints
should not be stressed for 24-48 hours, so that the cross-linking
reaction can occur.
Where does the moisture that fuels the reaction come from?
Moisture from the air and substrates fuels the reaction. The amount of
moisture may affect the set time and cure time of the adhesive.
Will I need to use clamps?
Although clamping or bracing can ensure a good bond, HiPURformer™
adhesives greatly reduce the need for this application. HiPURformer™
is the ideal choice for projects that are difficult to clamp and require a
fast, strong bond.
How can I prolong the shelf life of the adhesive?
If unopened, the cartridges should be kept in the foil pouch and stored
in a cool, dry location. Do not expose to rain or moisture. Before
shutting down for the day, extrude
a one-inch bead of adhesive to
ensure that any air has been
purged from the cartridge tip
and immediately replace the
cartridge cap tightly while the
adhesive is hot. CAUTION: Do
not touch applicator heat
cylinder or cartridge when at
maximum temperature. Always
wear gloves.
Titebond Technical Help Line 1-800-347-GLUE