Plug-in Reference
Table Of Contents
- Table of Contents
- The Included Effect Plug-ins
- MIDI Effects
- The Included VST Instruments
57
The Included Effect Plug-ins
EQ Plug-ins
Global Plug-In Settings
The global plug-in settings can be accessed via the Settings window. The following
parameters are available:
Level meter
settings
– Density
mode
Activates the density metering mode. In this mode you can see
levels at which a signal stays often. By examining the range of levels
at which a signal stays, you can draw conclusions about the
effective dynamic range of the material.
Note that the signal level estimation is affected by the meter’s
integration and release times. In this mode, the display of the signal
level is also affected by the Peak Level hold time setting.
Level meter
settings
–
Integration time
Affects the level integration time of all level meters. The value
reflects the time it takes for a signal level to fall down by 20
dB, or
raise up from one steady level to another steady level.
Note that this setting does not affect the peak level on the level
meters, but directly affects the visible difference between the peak
and RMS levels when a musical signal is measured.
Level meter
settings
– Release
Time
Changes the level meter’s release time. This is the time it takes for a
signal to fall down by 20
dB.
Level meter
settings
– Peak level
hold time
Adjusts the time that a registered peak level with a width of 1
sample stays unchanged on the level meter.
Parameter Description
Parameter Description
Mouse Wheel
Precision
Affects the precision of the mouse wheel. The higher the precision,
the finer the value changes using the mouse wheel.
SHIFT Key Precision Affects the precision when using the [Shift] key and dragging a
control with the mouse.
Drag Precision Affects how quickly knobs and readouts react to mouse
movements.