Datasheet

2
FPI 118FPI 018 FPO 118FPO 018
25
124
152
66
35
25
124
25
124
152
66
35
25
124
25
124
152
66
35
25
124
152
79
25
124
124
25
22
152
79
25
124
124
25
22
124
25
PRODUKTKATALOG - STEGO
FILTER MAT FM 086
Filter class 118 x 118 mm Average arrestance A
a
1 packing unit
G3 acc. to DIN EN 779 Art. No. 08634.0-00 84 % 5 pieces
AIRFLOW DIRECTION "OUT": FILTER FAN FPO 018
Art. No. Operating voltage Air volume,
free flow
Air volume
with exit filter
Current consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Depth in
enclosure
Weight
(approx.)
Air outlet
01881.0-00 AC 230 V, 50/60 Hz 97 m³/h 47 m³/h 120 mA 19 W 49 dB 79 mm 0.9 kg air-flaps
01881.9-00 AC 115 V, 50/60 Hz 117 m³/h 58 m³/h 230 mA 18 W 52 dB 79 mm 0.9 kg air-flaps
AIRFLOW DIRECTION "OUT": INTAKE FILTER FPO 118
Art. No. Depth in enclosure Weight (approx.) Filter mat
11881.0-30 22 mm 0.2 kg G3 acc. to DIN EN 779, average arrestance A
a
84 %
TECHNICAL DRAWINGS
warmcold
Filter Fan FPO 018
Intake Filter FPO 118
Air-flaps
Filter mat
SYSTEM FPO
2
TECHNICAL DATASHEET
www.stego.de | www.stego.co.uk | www.stegonorden.se11.11.2015 | Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.