User manual

13
741.011 | 12.18
EN
Selecting a system
6. Press . System 1.1 is displayed, 1.1 flashes (Fig. left).
7. Press  to select a different system.
8. Press SET.
If System 0.1 was selected in step 7, then continue with
step 18.
Setting pump 1 (output R1)
9. Press . AC and flash (example in Fig. left).
10.
Notice
Standard pump: Select AC!
High-efficiency pump: Select HE!
Press  to set the type of pump 1.
11. Press SET.
12.
Notice
Pay attention to the pump characteristics when selecting HE
(high-efficiency pump).
Only if HE was selected in step 10:
Press  to set the characteristics of the high-efficiency
pump; see Tab. 2 and Fig. 6 on p. 15.
13. Press SET:
If AA or Ab was selected in step 12, SC is displayed; off,
and
flash (example in Fig. left; SC = Speed control).
If C was selected in step 12, then continue with step 18.
14. Press  to switch on the speed control if necessary (on
flashes).
15. Press SET.
If off was selected in step 14. then proceed wit step 18.
16. min, value %,
and flash.
Press  to set the minimum speed of pump 1 in %.
17. Press SET.
18. Press . F: is displayed.