Datasheet
COOLCEPT / COOLCEPT-X / COOLCEPT³ / COOLCEPT³-X / COOLCEPT FLEX
StecaGrid 3203x StecaGrid 4003x StecaGrid 4803x StecaGrid 5503x
DC input side (PV generator)
Maximum input voltage 1000 V
Operating input voltage range 250 V … 800 V
Number of MPP tracker 1
Maximum input current 11.0 A
Maximum short circuit current +20 A / -13 A
Maximum input power at maximum active
output power
3300 W 4100 W 4920 W 5620 W
AC output side (Grid connection)
Grid voltage 320 V … 480 V (depending on regional settings)
Rated grid voltage 400 V
Maximum output current 7.0 A 7.0 A 10.0 A 10.0 A
Maximum active power (cos phi = 1) 3200 W 4000 W 4800 W 5500 W
Maximum active power (cos phi = 0.95) 3040 W 3800 W 4560 W 5225 W
Maximum active power (cos phi = 0.9) 2880 W 3600 W 4320 W 4950 W
Maximum apparent power (cos phi =
0.95)
3200 VA 4000 VA 4800 VA 5500 VA
Maximum apparent power (cos phi = 0.9) 3200 VA 4000 VA 4800 VA 5500 VA
Rated power 3200 W 4000 W 4800 W 5500 W
Rated frequency 50 Hz and 60 Hz
Frequency 45 Hz … 65 Hz (depending on regional settings)
Night-time power loss < 3 W
Feeding phases three-phase
Total harmonic distortion (cos phi = 1) < 1 %
Power factor cos phi 0.8 capacitive … 0.8 inductive
Characterisation of the operating performance
Max. efficiency 98.6 % 98.6 % 98.7 % 98.7 %
European efficiency 97.9 % 98.1 % 98.2 % 98.3 %
Californian efficiency 98.3 % 98.4 % 98.5 % 98.5 %
MPP efficiency > 99.8 % (static), > 99 % (dynamic)
Own consumption < 8 W
Power derating at full power from 50 °C (T
amb
) 50 °C (T
amb
) 50 °C (T
amb
) 45 °C (T
amb
)
Safety
Isolation principle no galvanic isolation, transformerless
Grid monitoring yes, integrated
Residual current monitoring yes, integrated (The design of the inverter prevents it from causing DC leakage current)
Operating conditions
Area of application indoor rooms with or without air conditioning, outdoors with or without protection
Climate protection class as per IEC
60721-3-4
4K4H
Ambient temperature -25 °C … +60 °C
Storage temperature -30 °C … +70 °C
Relative humidity 0 % … 100 %, non-condensating
Noise emission (typical) 29 dBA
Fitting and construction
Degree of protection IP 65
Overvoltage category III (AC), II (DC)
DC Input side connection Phoenix Contact SUNCLIX (1 pair), mating connector included
AC output side connection Wieland RST25i5 plug, mating connector included
Dimensions (X x Y x Z) 399 x 657 x 227 mm
Weight 12.0 kg
Communication interface RS-485 (2 x RJ45 sockets; connectable to Meteocontrol WEB‘log or Solar-Log™), Ethernet interface (1 x RJ45)
Integrated DC circuit breaker yes, compliant with VDE 0100-712
Cooling principle temperature controlled fan, variable speed, internal (dustproof)
Test certificate see certificate download on the product page
Powered by TCPDF (www.tcpdf.org)
Version 2018-03-23 13:49 Steca Elektronik GmbH | Mammostraße 1 | 87700 Memmingen | Germany | info@steca.de | www.steca.de