3. Press SET. The Delete slave dialogue appears (Fig. left).
4. Hold SET pressed for 1 s. The selected slave is deleted.
Synchronising slave
NOTICE!
The Synchronise slave function actively transfers the parameter settings of the MPPT 6000-
M master to all MPPT 6000-S slaves.
StecaLink PA HS400 slaves are not synchronised. No configurable data is stored in the PA
HS400.
Each MPPT slave executes a reset after receiving the information, in order to adopt the
new values.
The reset interrupts charging, switches off the module and battery relays and executes a
complete restart of the device.
Charging is started again after a restart caused by synchronising, depending on the
configuration of the slaves, see
Ä
‘Configuring the operating mode’ on page 89 and the
Device On/Off state of the master.
The restart causes each MPPT 6000-S to perform a new system voltage detection, see
Ä
Chapter 4.4 ‘Supplying the controller with voltage’ on page 31.
If ‘Save setting’ is set for the slave in the Configuration MPPT slave menu ,
see
Ä
‘Configuring the operating mode’ on page 89, then the settings are saved in the
MPPT 6000-S.
Synchronising
‘Main menu è System settings è StecaLink master menu
è Synchronise
1. Press SET. The Synchronise slave dialogue appears (Fig.
left).
2. Hold SET pressed for 1 s. The transmission is started.
3. The display automatically changes to the higher-level menu.
8.9 Internal data logger
The data logger stores the following data in the internal memory:
n Energy input
n Energy output (MPPT 6000-M only)
n Min. battery voltage
n Max. battery voltage
n Max. charging current
n Max. PV 1 voltage
n Max. PV 2 voltage
756.404 | Z01 | 16.06