User manual

Table Of Contents
8.8.1 StecaLink slave address setting
StecaLink slave address
NOTICES
n Setting of the device address used for identifying the
device as a StecaLink slave node.
n Every device in a StecaLink communication network must
have a unique device address.
n Problems/error messages will occur during device
registration if multiple devices have the same address.
‘Main menu è System settings è StecaLink slave addr.
1. Press SET. The RS485 address dialogue appears (Fig. left).
2. Press SET. The value flashes.
3.
Press D, Ñ to change the value.
4. Press SET. The value stops blinking.
8.8.2 StecaLink master setting (MPPT 6000-M only)
NOTICE!
The master device in a StecaLink communication network controls the flow of data to the
StecaLink slave members.
The StecaLink slave members must be registered at the master device. Configuration of the
slaves must be performed at the master, depending on the type and functional scope of
each respective slave.
See
Ä
Chapter 6.6 ‘StecaLink master connection (MPPT 6000-M only)’ on page 48 for
cabling information.
Add slave device
‘Main menu è System settings è StecaLink master menu
è Add slave device
1. Press SET. The Set slave address dialogue appears (Fig.
left).
2. Press SET. The value flashes.
3.
Press D, Ñ to change the value.
4. Press SET. The value stops blinking. The StecaLink master
queries the entered address.
The detected StecaLink slave member is displayed (Fig. left).
5. Press SET. If additional settings for the registered slave are
possible then an additional menu is displayed.
For information on the further configuration parameters, see
‘Change slave settings’ (
Ä
‘Change slave settings’
on page 87).
756.404 | Z01 | 16.06