User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Current limit system: On/Off
✔
‘Main menu è Battery settings è Current limit system’
1. Press SET. The Current limit system menu appears (Fig.
left).
2.
Press D, Ñ to select the menu item On/Off.
3. Press SET. The Current limit system dialogue appears
(Fig. left).
4.
Press D, Ñ to select On/Off.
5. Press SET. Control of the maximum system charge current is
switched on or off accordingly.
Current limit system: Value
✔
‘Main menu è Battery settings è Current limit system
’
1. Press SET. The Current limit system menu appears (Fig.
left).
2.
Press D, Ñ to select the menu item Value.
3. Press SET. The Current limit system dialogue appears
(Fig. left).
4. Press SET. The value flashes.
5.
Press D, Ñ to change the value.
6. Press SET. The value stops blinking.
8.4 Current limit device setting
NOTICE!
It may be necessary to limit the maximum charge current used for charging the battery. The
specifications and notes of the battery manufacturer must be adhered to. Take care to observe
the specifications of the battery management system (BMS) when using Li-Ion batteries. This
limit is set to the maximum possible current of 60 A in newly delivered MPPT 6000-M and MPPT
6000-S devices.