User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

4. Terminate the free ‘StecaLink slave’ connection of the last slave member using the
termination plug.
Tarom
MP
PT 6000-M
StecaLink
Slave Slave
StecaLink
Master
Tarom
MP
PT 6000-S
StecaLink
Slave Slave
......
Tarom
MP
PT 6000-S
StecaLink
Slave Slave
PA HS400
S
tecaLink
Slave Slave
......
PA HS400
S
tecaLink
Slave Slave
Term.
Fig. 8: Bus cabling example using an MPPT 6000-M, MPPT 6000-S and PA HS400 current sensors
Tarom
MP
PT 6000-M
StecaLink
Slave Slave
StecaLink
Master
PA HS400
St
ecaLink
Slave Slave
......
PA HS400
St
ecaLink
Slave Slave
Term.
Fig. 9: Bus cabling example using an MPPT 6000-M and additional PA HS400 current sensors
Tarom
MPP
T 6000-M
StecaLink
Slave Slave
StecaLink
Master
PC
StecaLink
Master
Fig. 10: Example of connecting a PC to the MPPT 6000-M, e.g. for the update function
Tarom
MPP
T 6000-M
StecaLink
Slave Slave
StecaLink
Master
Tarom
MPP
T 6000-S
StecaLink
Slave Slave
Fig. 11: Connection of the MPPT 6000-M slave connection to other MPPT 6000-S or PA HS400 slave
connections is not permitted
756.404 | Z01 | 16.06
46