User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Set Set
Set
Set
Set
Set
Same scope of settings for AUX1/2/3
Set
Set Set
*5
Set
*5
Set
*5
Set
Set
Set
Set
Set
Set
*1) MPPT 6000-M only
*3) SOC Control mode only
*5) Separate entry of hh and mm, therefore press multiple times to change to the next window
Set Set
Set
Set
*1) MPPT 6000-M only
Same scope of
settings for timer 1/2/3/4
*4) Voltage control mode only
Settings AUX 1/2/3
*1
AUX 1
AUX 2
AUX 3
Operation mode
Deep disc harge prot.
Select function
Function settings
AUX operation mode
[ ] On
[ ] Off
[ ] Function
Disconnection threshold
SOC *3 / V *4
Reconnection hysteresis
SOC *3 / V *4
Select AUX function
[ ] Evening light
[ ] Night light
[ ] Morning light
[ ] Generator control
[ ] Excess energy control
[ ] Timer 1
[ ] Timer 2
[ ] Timer 3
[ ] Timer 4
Evening light
Night light
Morning light
Generator control
Excess energy control
Timer 1
Timer 2
Timer 3
Timer 4
Switch-on delay
00:00
Switch-on duration
00:00
Switch-on delay
00:00
Switch-off delay
00:00
Switch-off delay
00:00
Switch-on duration
00:00
Starting threshold
SOC *3 / V *4
Hys teresis
SOC *3 / V *4
Starting threshold
SOC *3 / V *4
Hys teresis
SOC *3 / V *4
Switch-on day
MON_TUE_WED_THU_FRI_SAT_SUN
Switch-on time
00:00
SD card
*1
Datalogger On/Off
Load parameter
Store parameter
[ ] On
[ ] Off
Load parameter
[ ESC ] [ 1s ]
Switch-off day
MON_TUE_WED_THU_FRI_SAT_SUN
Switch-off time
00:00
A)
B)
Store parameter
[ ESC ] [ 1s ]
Set Set
Set
Set
Set
Set
Same scope of settings for AUX1/2/3
Set
Set
Set
*5
Set
*5
Set
*5
Set
Set
Set
Set
Set
Set
*1) MPPT 6000-M only
*3) SOC Control mode only
*5) Separate entry of hh and mm, therefore press multiple times to change to the next window
Set Set
Set
Set
*1) MPPT 6000-M only
Same scope of
settings for timer 1/2/3/4
*4) Voltage control mode only
Settings AUX 1/2/3
*1
AUX 1
AUX 2
AUX 3
Operation mode
Deep discharge prot.
Select function
Function settings
AUX operation mode
[ ] On
[ ] Off
[ ] Function
Disconnection threshold
SOC *3 / V *4
Reconnection hysteresis
SOC *3 / V *4
Select AUX function
[ ] Evening light
[ ] Night light
[ ] Morning light
[ ] Generator control
[ ] Excess energy control
[ ] Timer 1
[ ] Timer 2
[ ] Timer 3
[ ] Timer 4
Evening light
Night light
Morning light
Generator control
Excess energy control
Timer 1
Timer 2
Timer 3
Timer 4
Switch-on delay
00:00
Switch-on duration
00:00
Switch-on delay
00:00
Switch-off delay
00:00
Switch-off delay
00:00
Switch-on duration
00:00
Starting threshold
SOC *3 / V *4
Hysteresis
SOC *3 / V *4
Starting threshold
SOC *3 / V *4
Hysteresis
SOC *3 / V *4
Switch-on day
MON_TUE_WED_THU_FRI_SAT_SUN
Switch-on time
00:00
SD card
*1
Datalogger On/Off
Load parameter
Store parameter
[ ] On
[ ] Off
Load parameter
[ ESC ] [ 1s ]
Switch-off day
MON_TUE_WED_THU_FRI_SAT_SUN
Switch-off time
00:00
A)
B)
Store parameter
[ ESC ] [ 1s ]
Set
Set Set
Set
Event log
E)
01/30 Event message
30/30 Event message
F)
Information
Contact info
System info
Manufacturer
Address
Email
QR code
Platform name
Serial num.
PU version
- APP
- FBL
- BFAPI
- HW
SYS version
- BFAPI
- FBL
- APP
- PAR
- HW
MPPT slave address
Manual
756.404 | Z01 | 16.06
18